Figure 5: Enclosure internal view
The main characteristics of the enclosure are detailed hereafter:
Description
Specification
Enclosure material
Aluminum
Gasket material
TPE
Mounting kit material
Stainless steel
Color
RAL 9010
Dimensions with connectors
300 x 280 x 120 mm
Dimensions with conn mounting kit
300 x 320 x 125 mm
Weight – no modules
5.4 Kg
Weight – 3 modules configuration
7.2 Kg
Weight – Full-Duplex version
10Kg
Ingress protection
IP66 / EN 60529
Humidity
95% non-condensing
Impact resistance
IK08
Flammability rating
UL94-V0
Number of pressure equalizer
2
Enclosure temperature range
-40°C to +120°C
Wirnet iBTS operating temperature range
-20°C to +55°C
Connectors
1 x M25 cable gland (PoE)
3 x N-SMB adapters (extension to 11 max)
8 x M16 blind stops (provisions for N-SMB or
cable gland)
Mounting
kit
M25 cable
gland (PoE)
N-SMB
adapters
M16 blind
stops
Sticker for regulatory
(FCC, IC, ANATEL, …)
Screw-in
vents
Sticker w/ serial
number, regulatory, …
Blind
threaded
standoffs