43
increments. However, it then takes longer to adjust the brightness when the brightness settings are changed.
Number of measurements (Msr rnge)
This parameter allows you to define how many individual measurements the light sensor uses to calculate an average
before using this value for control. The higher you set this parameter, the less sensitive the control is to interference
(e.g. light from tractor headlights or lightning). However, the lights are also adjusted more sluggishly the higher you
set this parameter.
Reaction variation (Reaction var.)
The reaction variation is a permitted tolerance between the sensor reading and the desired brightness. The control only
readjusts the brightness when there is a larger variation. If you increase this value, the control does not achieve the
desired brightness as precisely. If you lower the value, you risk causing the control to oscillate (the light is continually
readjusted and repeatedly gets lighter and darker).
11. Technical data / Documentation
Designation Value
Power supply
230 / 400 V, 50 Hz
Supply cable fuse
Three-pole B16 A circuit-breaker
Maximum current output of light circuits Circuit 1: 16 A
Circuit 2: 16 A
Circuit 3: 8 A
Circuit 4: 8 A
Maximum input surge current per circuit 30 A for 5 ms
min cos
φ
0.8
Interface of circuits 1 and 2
0–10 V
Button interface
NO contact 12 VDC
Operating temperature
10 °C–40 °C
Protection type
IP 65
Dimensions
450 x 300 x 142 mm
Control voltage
12 VDC
You can find the circuit diagram at the end of these operating instructions.
Summary of Contents for 345000
Page 45: ...45...