background image

©2012, KEPCO, INC

1

Data subject to change without notice

228-1546 REV 4

I N S T R U C T I O N   M A N U A L

KEPCO

 KEPCO, INC. 

   

 131-38 SANFORD AVENUE 

 

  FLUSHING, NY. 11355 U.S.A.

 

  TEL (718) 461-7000

 

 

 FAX (718) 767-1102

 

http://www.kepcopower.com   

 

 email: [email protected]

An ISO 9001 Company.

MTW

60W

60 WATT TRIPLE OUTPUT 

SWITCHING POWER SUPPLY

I — INTRODUCTION

SCOPE OF MANUAL. 

This instruction manual covers the installation and operation of the Kepco MTW 60W Switching Power Supply,

Model MTW 60-51212K. 

DESCRIPTION. 

The Kepco MTW 60W is a PC card style, triple-output switching power supply. Units may be operated with a nominal 100 to

120V a-c and 220 to 240V a-c (input voltage range 85 to 265 Va-c), 50-60 Hz (input frequency range 47-440Hz). They will also operate on

110V to 370V d-c input. The MTW 60W employs a light weight ferrite core with 70 KHz switching frequency for the +5V output and 100KHz for

the ±12V outputs. Regulation is provided by pulse width modulation. A FET power stage, operating in the flyback mode provides smooth iso-

lated d-c outputs. A trimmer provides fine adjustment of the 5V output. The ±12V outputs have a common return. DC Output power is shared

b5V, +12V and -12V (60W max. total). A thermistor circuit prevents excessive turn-on current surge. Overvoltage protection is pro-

vided. Overcurrent protection with automatic recovery from short circuit is featured. A steel cover (Model CA 41) is available as an option.
Table 1 contains output specifications. Section II (following) contains specifications and operating limits.

II — SPECIFICATIONS

The following specifications are at nominal input voltages at 25°C unless otherwise specified.

INPUT VOLTAGE:  

CAUTION:

 Operation at voltage below specified range for more than 10 minutes may cause component degradation.

Nominal 100-120V a-c, 200-240V a-c, range: 85-265V a-c (0 to 100% load, -10 to 60°C)

 d-c range: 110 -370V d-c (Safety agency approval applies only to a-c input operation.)

INPUT SOURCE FREQUENCY: 

Nominal 50/60 Hz; Range 47-440 Hz. (0 to 100% load, -10 to 60°C). At 440 Hz the leakage current exceeds the VDE safety specification

limit.

TABLE 1.   MTW 60W OUTPUT SPECIFICATIONS

SPECIFICATION

OUTPUT 1

OUTPUT 2

OUTPUT 3

CONDITON

OUTPUT VOLTS, d-c

5V

+12

 –12V

+5V floating from ±12V

SETTING TOLERANCE (V)

4.9-5.1

11.4-12.6

11.4-12.6

ADJUSTMENT RANGE

5.00-5.25

(6)

FIXED

FIXED

OUTPUT

CURRENT

(A)

RATED

5.0

2.5

0.5

MINIMUM

0

0

0

PEAK

(5)

7.0

3.5

0.7

Within 10 seconds.

SOURCE EFFECT

1% max.

0.4% max.

0.4% max.

85-132Va-c, 170-265Va-c

LOAD EFFECT

2% max.

2% max.

1% max.

10-100% load

TEMPERATURE EFFECT

2% max.

2% max.

1% max.

-10 to 50°C

COMBINED EFFECT

2.5% max.

2.5% max.

2% max.

Overshoot at startup: 4% typ.

TIME EFFECT (Drift)

1% max.

1% max.

1% max.

1/2 to 8 hr.

OVERCURRENT (AMPS) 

(2)

7.4 min.

3.7 min.

0.75 min.

OVERVOLTAGE SETTING (VOLTS)

(3)

5.8 min.

13.8 min.

-

EFFICIENCY (typ.)

100 Va-c

76%

76%

76%

240 Va-c

76%

76%

76%

ACCEPTABLE OUTPUT CAP.

(4)

 (µFmax.)

10000

5000

3000

Fixed load resistance

RIPPLE

AND

NOISE

(1)

(mV p-p)

ripple (typ)

80

100

100

ripple (-10-0ªC)

140 max.

160 max.

160 max.

spike noise (typ)

120

150

150

spike noise (-10-0ªC)

160 max.

180 max.

180 max.

(1)

Switching component 

 20KHz, 0 to 100% load, 0 to 60 

°C, tested with 100µF electrolytic and 0.1µF film capaci-

tors across the load and connected to the power supply 

via 5.9 in (150mm) wires.

(2)

Hiccup type; automatic recovery after cause of overcur-

rent is removed. Avoid overcurrent operation to prevent 

component degradation.

(3)  Zener diode clamp method; protects load against faulty power supply; 

operation could require power supply service.

(4)

+5V output may drop during startup.

(5)

Peak current acceptable as long as rms output current within 10 seconds is 

within rated value.

(6)

Adjustable using 5V Output Voltage Adjustment trimpot.

Reviews: