3-20
KLN 750W 121912
3.3.44
IP ADDRESS RESET
The IP Address reset function resets the IP Address and Subnet Mask address to the default
value of 192.168.0.100 and 255.0.0 respectively.
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(RSTI) to access RESET IP ADDRESS function.
2. Press ENTER key to view setting.
OFF (default) displayed as
(oFF) in Current display.
ON mode displayed as
(on) in Current display to initiate RESET IP ADDRESS.
3. Rotate encoder until Current display shows
, then press ENTER to confirm.
3.3.45
VIEWING ERROR CODES.
When the red
(alarm) LED on the front panel is lit, use the ERR function of the menu to read
the error.
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(ERR) to access Error Codes.
2. Error code displayed in Current display
(0, no error). Refer to Table B-2 for a
complete list of error codes.
3. Press ENTER key to erase code in Current display and read the next error code. When Cur-
rent display reads 0, all error codes have been read.
3.4
SERIES/PARALLEL OPERATION
The following paragraphs describe operation of multiple units connected in series or parallel
3.4.1
SERIES OPERATION
•
The front panel voltage displays of the Master and Slave each show 1/2 of the total output
voltage of the series combination. The front panel current display of the Master shows the
current for the series combination
•
The voltage monitoring function at pin 20 (V MON) of the Control Programming port is func-
tional for both Master and Slave, 0 - 10V corresponding to 0 to full scale voltage of the indi-
vidual units. Voltage monitor for the series combination is the sum of the output of pin 20 of
the Master plus pin 20 of the Slave.
•
The current monitoring function at pin 22 (A MON) of the Control Programming port is func-
tional for both Master and Slave, 0 - 10V corresponding to 0 to full scale current of the indi-
vidual units.
•
The alarm status function at pin 9 (ALARM) of the Control Programming port is functional for
both Master and Slave. If the Master alarm status is active, the Master and Slave will be
shut down. If the Slave alarm status is active, only the Slave will be shut down.
•
When using remote control, only the Master can be operated and controlled by remote com-
mands.