3-14
KLN 750W 121912
3.3.23
SET 4TH PART OF IP ADDRESS (LAN INTERFACE ONLY)
Used to set fourth part (nnn) of the 4-part IP address (xxx.xxx.xxx.nnn) where nnn can be set
from 0 to 254.
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(S.IP4) to access fourth part of IP address.
2. Press ENTER key to view setting.
For example,
(100) displayed in Current display for IP Address xxx.xxx.xxx.100.
3. Rotate encoder until Current display shows desired setting (tap encoder to adjust 10’s or
100’s digit more rapidly). Press ENTER to confirm.
3.3.24
PARALLEL/SERIAL MASTER/SLAVE SETUP
Used to establish unit as Master or Slave for parallel (maximum of five units including Master) or
series operation (maximum of two units including Master).
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(PSOP) to access Parallel/Serial Master/Slave Setting.
2. Press ENTER key to change setting.
Parallel Master displayed as
(PM) in Current display.
Parallel Slave displayed as
(PS) in Current display.
Serial Master displayed as
(SM) in Current display.
Serial Slave displayed as
(SS) in Current display.
3. Rotate encoder until Current display shows desired setting, then press ENTER to confirm.
3.3.25
EXTERNAL CONTROL OF OUTPUT ON/OFF
This function enables or disables external control of output on/off using the Programming Con-
trol port.
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(EO.C) to access EXTERNAL OUTPUT ON/OFF CONTROL function.
OFF (default) displayed as
(OFF) in Current display.
ON displayed as
(ON) in Current display.
2. Press ENTER key to change setting. Rotate encoder until Current display shows desired
setting, then press ENTER to confirm.
3.3.26
ENABLE VOLTAGE CONTROL VIA PROGRAMMING CONTROL PORT
Allows voltage control either from the front panel (LOCAL) or from the analog signal via the Pro-
gramming Control port (EXTERNAL)