3.3.3.1
SELECTING BIPOLAR/INDEPENDENT PROTECTION LIMITS
The BOP can be configured to allow the protection limits to be displayed and changed from the
front panel as either a single value that applies to both protection channels or as individual set-
tings for positive and negative protection limits. Selecting Independent protection limits means
that the positive and negative limits are displayed (and can be modified) independently. Bipolar
means that for each protection limit (voltage or current) a single value applies to both the posi-
tive and negative limits; only one value is displayed and can be edited for both ± protection lim-
its.
If the MAX/MIN Protect Settings are not symmetrical when Protect Entry is set to Bipolar, the
protect setting can be adjusted from 0 to the higher protection limit from the front panel; the unit
automatically limits the lower protection limit to the MAX/MIN settings value.
For example, if the unit is in Current mode with +V Protect Max set to 10, -V Protect Max set to
5 and Protect Entry set to Bipolar, setting VPROTECT to 4 from the front panel sets both the
positive and negative protection levels to 4. Adjusting VPROTECT to 6 sets the positive protec-
tion level to 6 but the negative protection level is automatically limited to 5 by -V Protect Max
with no errors or warnings generated.
Press
#
from the power-up screen to enter the Display Settings menu (Figure 3-7), then high-
light Protect Entry and press
!
to change it. Highlight Bipolar or Independent, then
$
to
save, or
%
to abort. When complete, press
$
to save for power-up,
#
to abort, or
%
to
apply the changes (without saving for power-up) and exit.
FIGURE 3-8. GENERAL SETUP MENU
VOLTAGE
SOURCE
VOLTAGE
CURRENT
0.0000 0.0000
Summary of Contents for BOP-ME 1KW
Page 2: ......
Page 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 42: ......
Page 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 76: ......
Page 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Page 164: ......