Check the Electrical Supply Requirements
This product must be installed in accordance with national, state and local electric codes. The
following table provides the correct voltage, amperage and frequency that must be supplied to the
grill.
The supply must be from an individual grounded circuit that is protected by a circuit breaker and
rated per the specifications for the model as shown in the table below.
KENYON
Max Load
Power Supply
Plug Type
Part #
B70400
2600 Watts
240V AC 11A 60Hz
Flying leads in flexible conduit
(designed to be hardwired into
electrical system)
WARNING:
If the electrical supply does not meet the product specifications, consult with a
licensed electrician before proceeding with installation!
Your Texan Grill is supplied with a factory installed polished stainless steel flange that accepts
nine oval head wood screws for mounting. The trim flange of the grill is designed to hold the unit
firmly in place in the countertop. If desired, you may seal the edge of the countertop beneath the
trim flange. We recommend a NON-ADHESIVE such as acrylic latex caulk. This will help reduce
the chance of damage to the trim flange should the unit need to be removed from the countertop.
Should you need to remove the unit from the countertop after installation simply take a piece of
fishing line and run back and forth under the trim flange to break the caulk bond.
WARNING:
Allow a 2 inch (2”) minimum clearance between the bottom of the grill and combustible
surface located below, ie: the upper edge of a drawer installed below the grill (Fig. 6, page