67
Software 09
System Configurations
The typical system configurations that use the TS-890S and Windows software are described below.
Refer to “TS-890S KENWOOD NETWORK COMMAND SYSTEM Setting Manual” which describes detailed information
on the configuration method for remote control.
■Controlling the TS‑890S from an Adjacently‑placed PC (with a
Microphone Connected to the TS‑890S and an Internal Speaker)
● Using the LAN connector
Signal Type
PC
Connection
Method
TS‑890S
Software
Hardware
Hardware
Control
signal
ARCP-890
-
LAN Cable
Connect to the
LAN
connector
Audio signal
-
-
No
connection
Microphone connected to the TS-890S
and internal speaker
Note:
◆ Configure “On (LAN)” in “KNS Operation (LAN Connector)” of the TS-890S.
● Using the USB connector
Signal Type
PC
Connection
Method
TS‑890S
Software
Hardware
Hardware
Control
signal
Virtual COM port
driver and ARCP-890
-
USB cable
Connect to the
USB‑B
connector.
Audio signal
-
-
No
connection
Microphone connected to the TS-890S
and internal speaker
Note:
◆ With these system configurations, the bandscope screen refreshes at a slower speed.
● Using the COM connector
Signal
Type
PC
Connection
Method
TS‑890S
Software
Hardware
Hardware
Control
signal
ARCP-890
-
RS-232C
cable
Connect to the
COM
connector.
Audio signal
-
-
No
connection
Microphone connected to the TS-890S
and internal speaker
Note:
◆ With these system configurations, the bandscope screen refreshes at a slower speed