6 EDIT MENU
39
Field Programming Reference (FPRG)
6.6
Scan Information Window
It can configure the Scan operation and conditions on the
“Scan Information” window. (Refer to FUNC 16 Scan.)
Figure 6-13 Scan Information window
6.6.1
Priority
This is a priority channel type to be scanned periodically.
You can select the mode from None, Fixed, and Selected
from the dropdown list.
TKR-750/850/751/851 scans channels in numerical order
(Normal Scan) when the priority scan function is selected
None.
Note:
!
You cannot configure the Priority Channel, Look Back Time A,
and Look Back Time B when priority is configured as “None”.
!
You cannot configure the Priority Channel when priority is
configured as “Selected”.
6.6.2
Priority Channel
This is a channel to be scanned periodically when TKR-
750/850/751/851 is scanning.
Select the channel configured as the Priority Channel
from the dropdown list or directly enter the channel
number.
Note:
!
You cannot configure this function if the “Priority” is configured to
“None” or “Selected”.
!
The dropdown list only displays the channel having the
configuration data.
6.6.3
Look Back Time A
This is a interval time to check the priority channel when
the scan is stopping on the normal channel and no signal
is on the priority channel. Configure the period by the spin
buttons or directly enter the value to configure the period.
Note:
It pauses on the Priority Channel when there is a signal to
receive and the signalling matches while scanning the
Priority Channel.
6.6.4
Look Back Time B
This is a interval time to check the priority channel when
the scan is stopping and a signal without same signalling
is on the priority channel. Configure the period by the spin
buttons or directly enter the value to configure the period.
Note:
It pauses on the Priority Channel when there is a signal to
receive and the signalling matches while scanning the
Priority Channel.
6.6.5
Revert Channel
This is a condition of channel to transmit during scanning.
Select the condition from the dropdown list.
Range
None
Not perform the Priority Scan.
Fixed
The channels configured as the priority
channel are scanned periodically.
Selected
The selected channel is configured as
the priority channel when changing the
channel.
Default
None
Range
1 - 16
Default
None
Range
0.5 - 5.0 sec.
In steps of
0.1 sec.
Default
0.5 sec.
Range
0.5 - 5.0 sec.
In steps of
0.1 sec.
Default
2.0 sec.
Range
Last Called
Last Used
Selected
Se Talkback
Priority
Pr Talkback
Default
Last Called