4 SOUNDS
22
Confidential
FUNC (K)/Ver. 1.01
4.4 Alert Tone Pattern
This function can be used to configure the Alert Tone
pattern when the transceiver receives a DTMF, 2-tone or
FleetSync call. An Alert tone matching a user’s
environment can be configured.
A maximum of 8 Alert Tones can be configured for Alert
Tone Pattern. An Alert Tone pattern consists of 16 tones.
Alert Tone Pattern can be configured by using KPG-101D.
Below is a list of configuration items for Alert Tone Pattern.
Table 4-9 Alert Tone Pattern
Configuration using KPG-101D
•
Configuring the Alert Tone Pattern (Refer to
FPRG 6.13 Special Alert Tone.)
4.5 PTT Release Tone
The PTT Release Tone function notifies a user that
communication has ended and the
PTT
switch was
released. With this function, the receiving party can easily
recognize the appropriate time to transmit since this tone
sounds when the caller finishes transmitting.
The transceiver transmits the PTT Release Tone prior to
finishing transmission when the caller releases the
PTT
switch.
Figure 4-1 PTT Release Tone
The transceiver can be configured to emit the PTT
Release Tone in Conventional Group.
The transceiver can be configured to send the Dispatch
ID or Telephone ID in Trunking System. This function
helps avoid emitting 2 or more different types of tones
simultaneously, since some repeaters have a similar
function for Telephone IDs.
The transceiver can be configured to emit the PTT
Release Tone by using KPG-101D.
Configuration using KPG-101D
•
Configuring the PTT Release Tone in
Conventional Group (Refer to FPRG 6.7.3
Conventional Tab - PTT Release Tone.)
•
Configuring the PTT Release Tone (Dispatch) in
Trunking System (Refer to FPRG 6.7.4 Trunking
Tab - Dispatch.)
•
Configuring the PTT Release Tone (Telephone) in
Trunking System (Refer to FPRG 6.7.4 Trunking
Tab - Telephone.)
Alert Tone Pattern
Description
Frequency
The tone frequency can be
configured. The frequency can be
configured between 400 and 2500
Hz in steps of 10 Hz. Gap is
configured when “No Tone” is
selected.
Length
The tone length can be configured.
The tone length can be configured
between 10 and 2500 ms in steps of
10 ms. No tone is emitted if 0 ms is
configured.
Cycle
The number of times that the Alert
Tone sounds can be configured. A
number from 1 to 255 can be
configured. The transceiver emits
an Alert Tone until manually stopped
when Infinite is configured. If the
transceiver is configured to emit the
Alert Tone several times, the
transceiver does not emit the Alert
Tone while the transceiver is
unmuted.
Interval
The timing to repeat the Alert Tone
can be configured. The interval can
be configured between 0 and 255 s
in steps of 1 s.
PTT Off
PTT Release Tone
PTT On
Transmit
Receive