RD-DV5-S/DV7-L/DV5MD-S
12
CIRCUIT DESCRIPTION
When the (
¡
)button in remote controller is pressed while the setting is displayed, the setting increases,
and a new setting is stored in RAM.
When the (
1
)button in remote controller is pressed while the setting is displayed, the setting increases,
and a new setting is stored in RAM.
When the (
¡
) or (
1
)button in remote controller is pressed continously, steps is change by 100ms period.
: Measurement value
6. MANUAL auxiliary adjustment mode (only low reflection disc)
Step No.
Setting Method
Remarks
Display
Step 1
Test mode STOP state
tsm e
Step 2
Press SKIP DOWN (
4
) button five times.
MANUAL auxiliary adjustment mode
MNU YOBI
-
Step 3
Press once the MD PLAY button.
Initial setting
î
Temperature measuring mode
TMP :
Step 4
Press SKIP DOWN (
4
) button.
Offset "0" setting
î
A signal offset tentative measurement
HAo :
Step 5
Press SKIP DOWN (
4
) button.
B signal offset tentative measurement
HBo :
Step 6
Press SKIP DOWN (
4
) button.
E signal offset tentative measurement
HEo :
Step 7
Press SKIP DOWN (
4
) button.
F signal offset tentative measurement
HFo :
Step 8
Press SKIP DOWN (
4
) button.
Laser ON
LON :
Step 9
Press SKIP DOWN (
4
) button.
ABMAXO measurement
ABM :
Step 10
Press SKIP DOWN (
4
) button.
Focus ATT (A signal) tentative setting
SAg :
Step 11
Press SKIP DOWN (
4
) button.
Focus ATT (B signal) tentative setting
SBg :
Step 12
Press SKIP DOWN (
4
) button.
Pit section LPFEFO measurement
PEF :
Step 13
Press SKIP DOWN (
4
) button.
Pit section COUT measurement
PCH :
Step 14
Press SKIP DOWN (
4
) button.
Groove section LPFEFO measurement
GEF :
Step 15
Press SKIP DOWN (
4
) button.
Groove section COUT level measurement
GCH :
Step 16
Press SKIP DOWN (
4
) button.
TCRMIO measurement
TCR :
Step 17
Press SKIP DOWN (
4
) button.
Tracking ATT (E signal) setting
SEG :
Step 18
Press SKIP DOWN (
4
) button.
Tracking ATT (F signal) setting
SFG :
Step 19
Press SKIP DOWN (
4
) button.
Indication of tracking EFMIO measurement
g MI :
Step 20
Press SKIP DOWN (
4
) button.
LPFABO measurement
ABL :
Step 21
Press SKIP DOWN (
4
) button.
Focus ATT (A signal) setting
SAG :
Step 22
Press SKIP DOWN (
4
) button.
Focus ATT (B signal) setting
SAB :
Step 23
Press SKIP DOWN (
4
) button.
TCRS signal offset measurement
TCO :
Step 24
Press once the MD STOP button.
MNU YOBI state
–
MNU
–
YOBI
-
• : Measurement value, : Set value : Account value
• When the (
⁄
) or (
!
) button in remote controller is pressed while the setting is displayed, the setting increases or decreases,
and a new setting is stored in ROM.
• When the (
⁄
) or (
!
) button in remote controller is pressed continuously, steps is change by 100ms period.
If the measurement value is within the OK range, " " appears on the 8th character.
OK range HAO, HB0, HEO, HFO : 0 0 0 h
±
2 0 0 h
ABM : 1E2h
∼
9C7h PEF : 20Dh
∼
785h
GEF : 20Dh
∼
785h TCR : 030h
∼
239h
ABL : 1E2h
∼
9C7h TCO : 00h
±
20h
Step 1
Test mode STOP state
[ t s m
e
]
Step 2
Press the SKIP DOWN(
4
) button six times. MANUAL adjustment menu
[ _ M N U _ A J S T _ ]
Step 3
Press once the MD PLAY button.
Initial setting
Temperature measuring mode
[ T M P : _
_ _ _ ]
Step 4
Press once the SKIP DOWN(
4
) button.
Laser ON
[ L O N : _ _ _ _ _ _ ]
Step 5
Press once the SKIP DOWN(
4
) button.
Innermost periphery move
Tracking ATT (E signal) setting
[ P E G :
]
Step 6
Press once the SKIP DOWN(
4
) button.
Tracking ATT (F signal) setting
[ P F G :
]
Step 7
Press once the SKIP DOWN(
4
) button.
Indication of tracking EFMIO measurement
[ P M I :
_ _ _ ]
Step 8
Press once the SKIP DOWN(
4
) button.
Focus ATT (A signal) setting
[ H A G :
]
Step 9
Press once the SKIP DOWN(
4
) button.
Focus ATT (B signal) setting
[ H B G :
]
7. MANUAL adjustment mode
High reflection disc
Step No.
Setting Method
Remarks
Display
If the MD STOP button is pressed twice while the MANUAL adjustment menu is displayed, the state is changed to the TEST
mode STOP state.