9.6.2.22. System - Import/Export
Here the user profiles can be exported or imported as CSV file. If user data can be provided by another system,
it can easily be imported here, which can be interesting especially on new systems with many users.
The export function will provide something like a template having at least the admin user in the file.
9.6.2.23. System - Help
Contains information for the support and version information of the AccessPoint.
9.6.3.
Master-Slave-mode (Compound operation with multiple AccessPoints)
Multiple AccessPoints can be connected together to one system.
For the one of the AccessPoints is configured as „Master“ via the web interface, all other AccessPoints as
„Slaves“. The advantage is, that configuration changes only have to be done on the „Master“ AccessPoint. The
master distributes the configuration to all slaves in the system.
The description for the setup of the Master-Slave-mode can be found under „DoorLock-devices with
AccessPoint“ earlier in this manual.
9.6.4.
Reset of components
In case of misconfiguration DoorLock-devices and AccessPoints can be reset to factory defaults.
DoorLock-devices
The reset deletes all configured RFID-cards except the Servicekey-card.
A deletion of the Servicekey-card is not possible.
For the reset please proceed as described here:
After the reset the DoorLock-device can be configured again.
At the online-cylinder at first the battery changing and dismantling card have to be read
(follow the steps for the initial setup in: „DoorLock-devices without AccessPoint“ ) .
AccessPoint
For a factory reset the AccessPoint is equipped with a reset-button. To perform the factory reset, please proceed
as described in the chapter „Default settings / factory defaults“ earlier in this manual.
Nr
Step
Note / Signalization
1
Present Servicekey-card (
yellow
) in front of the
DoorLock-device to start the programming mode.
Leave the Servicekey-card in front of the RFID-reader
until it quits the programming mode
(after approx. 15 seconds).
2
Present Servicekey-card in front of the device again
to start the programming mode a second time.
Leave the card in front of the RFID-reader.
3
The deletion process is signalized by multiple short
sounds. During the complete process the card has to
be held in front of the reader unit. Otherwise the
process will stop and has to be repeated.
1x long sound, 1x short sound
Wait for 5 seconds
1x long sound, 1x short sound
Multiple short sounds signalize the running deletion process.