Page 1: ...m a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Additional Safeguards Do not install wall oven beneath the work counter The oven vent should not be located under 36 from the floor Allow at least 19 3 8 clearance for comple...
Page 2: ...actured Home Construction and Safety Standard Title 24CFR Part 3280 Formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or when such standard is not applicable the Standard for Manufactured Home Installation 1982 Manufactured Home Sites Communities and Set Ups ANSi Z225 1 NFPA 501 A latest edition or with local codes Do not store items or food of interest to...
Page 3: ...th local codes or in their absence of local codes with the National Electric Code ANSI NFPA No 70 1987 or latest edition 3 Alternate construction Model with 11 2oven cavity only Installation Instructions for installing a 11 2 cavity oven into an existing 2 cavities opening with dimensions 42 1 8 height by 22 1 2 Width ght adjuster Wood runner Hywood filler Figure 3 If width opening is too wide to ...
Page 4: ...e appropriate holes in the side extension panels and sides of the oven Put the 6 screws back 5 Proceed with oven installation Return to upright position Oven Door Panel Figure 5 5 Cabinet Installation Insert appliance into cutout Use the 4 mounting screws provided to fasten the front frame of the appliance to the cabinet steps 1 below Keep the 2 decorative screws to fix the decorative trim to the ...
Page 5: ...t to stops Lift drawer front to clear stops and pull out Check for leaks After connecting gas check system for leaks with a manometer If a manometer is not available shut all pilots off if present turn on the gas supply to the unit and use a liquid leak detector at all joints and connections Tighten all connections if necessary to prevent gas leakage in the wall oven or supply line IMPORTANT A pip...
Page 6: ...n on Natural Gas Oven Burner Spud Figure 9 Using a 1 2 wrench turn down the adjustable spud which injects gas into the oven burner Turn spud approximately 21 2turns until snug against the LP metering pin Do not overtighten see figure 9 C Adjust Broiler Burner Orifice Self Cleaning Models Only see figure 10 Pin Air Shutter L Waist High Broiler Spud Figure 10 10 Adjustments Oven Broiler Flame Adjust...
Page 7: ...re Guide Check to make sure the house fuse or circuit breaker for your wall oven is not blown or open 11 Check Operation Refer to the Use and Care Guide packaged with the wall oven for operating instructions and for care and cleaning of your appliance Do not touch the oven burners They may be hot enough to cause burns 1 Check the Igniters some models Operation of electric igniters should be checke...
Page 8: ...instrucciones del abastecedor de gas En caso que no puede contactar el abastecedor de gas Ilame al departamento de bomberos La instalaci6n y el servido telef6nico deben ser realizados pot un instalador calificado pot un servido tecnico certificado o por el abastecedor de gas Medidas de seguridad adicionales o No instale homo de pared debajo de la mesa de trabajo La salida de descarga no debe estar...
Page 9: ... The Federal Standard for Mobile Home Construction and Safety title 24 HUD Part 280 O cuando estos estandares no sean aplicables The Standard for Manufactured Home Installation 1982 Manufactured Home Sites Communities and set ups ANSI Z225 NFPA 501 A _ltima edicion o codigos y regulaciones locales No almacene alimentos u otros objetos de interes para los ni_os en alacenas ubicadas encima de la est...
Page 10: ...de servicio de energia locales El incumplimiento las anteriores recomendaciones puede resultar en un peligroso coque electrico Nota Todas las conexiones y ajustes deben de ser realizados por un t_cnico calificado _2 1 Ajuste de altura ajuste inferior de altura de 1 2 Si la abertura es demasiado ancha para fijar la unidad al gabinete con tornillos de montaje ajuste con las tiras de relleno 3 2 X 4 ...
Page 11: ...utilizando los 2 tornillos decorativos proporcionados con el artefacto 6 Provea un adecuado suministro de gas Importante Lea estas instrucciones cuidadosamente antes de conectar esta unidad al suministro de gas Las unidades alas cuales se refieren estas instrucciones han sido disefladas para operar con gas natural de 4 WC o gas LP de 10 WC Se conecta un regulador convertible de presi6n en serie al...
Page 12: ...ticulaciones y conexiones para verificar si existen fugas Ajuste todas las conexiones en caso que sea necesario para evitar fugas de gas en la cocina o en el tubo de suministro de gas IMPORTANTE Para las uniones de tuberia debe usarse un sellante de uni6n de tuberia que sea resistente a la acci6n del gas LP No use ning0n tipo de llama para verificar si hay fugas de gas Verifique si hay fugas con u...
Page 13: ...ha de la wilvula aproximadamente 21 2 vueltas en el sentido contrario alas manecillas del reloj Esto separate1la capucha del pasador mezclador G Pase gas ajuste los pilotos y el quemador para obtener una llama conveniente H Debera haber 4 WC de presiOn en el multiple despu_s de este cambio para operar propiamente con gas natural Use un man0metro para chequear la presi0n en el multiple Si hay algun...
Page 14: ...te el quemador debe prender y permanecer encendido hasta que el homo alcance 300 F El quemador seguir_i alternando entre encendido y apago para mantener una temperatura promedia de aproximadamente 300 F Modelo y ubicaci6n del nurnero de serie La placa de serie est 1ubicada al interior del contramarco izquierdo del homo AsegOrese de incluir el modelo nOmero de serie y el nOmero o letra de Iote que ...
Page 15: ... 125 CL_251 3173 2 2O 125 CL1251 8173 CAUTION DISCONNECT POWER BEFORE SERVICING UNIT 318046316 REV B AVISO DESOONECTE LA ENERGIA ANTES DE REALIZAR EL NANTENI_IENTO DEL ELECTRODONESTICO PAGE 2 2 THIS SIDE OF THE SCHEMATIC IF YOUR APPLIANCE HAS A_ MEMBRANE SWITCH oS_N _ DE ESTE LADO DEL DIAGRAMA ESQUEMATICO SI SU ELECTRODOMESTICO TIENE _L_GUV r_ or co u o o BAKE IGNITER r_ q N_L ELECTRONIC OVEN CONT...
Page 16: ...ICING CONTROLS WIRING ERROR CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING AVISO ETIQUETE TODOS LOS ALAMBRES ANTES DE DESCONECTAR PAR REALIZAR ET MANTENIMIENTO DE LOS CONTROLES ERROR DE ALAMBRAJE PUEDE CAUSAR UN FUNCIONAMIENTO INCORRECTO Y PELZGROSO VERIQGE SI EL FUNCIONAMIENTO ESTA CORRECTO DESRUES DEL MANTENIMtENTO CAUTION DISCONNECT POWER BEFORE SERVICING UNI...