- 64 -
(2)
(1)
Sheath heater is a part for defrost. All heating wire is connected to only
one line. So we can decide part is defect or not when we check the
resistance.
Set a ohmmeter connect to The 2 housing pin.
Measure the 2 pin connected to Sheath Heater.
If the ohmmeter indicate (VXV)/Watt=R is good condition,
ex) when watt=350w, voltage=115v R=(115X115)/350=38‰
But the ohmmeter indicate infinitely great
Sheath heater is disconnection
Function
How to
Measure
Standard
Sheath heater (at all temperature)
34 ~42 ‰
(1) to (2)
Ressult
Test Point
7-2. Sheath Heater