background image

Summary of Contents for 5871540590 Guide

Page 1: ...Printed in U S Ao 154043601A ...

Page 2: ...ess to existing drain water and electrical lines Be sure the water inlet valve is protected from freezing If the valve freezes flooding may occur The best location for the dishwasher is on either side of the kitchen sink This provides access to plumbing and is convenient for loading i Tools Needed Measuring Tape Wire Stripper Pipe Joint or Knife compound For iron pipe plumb ing Electric Drill Leve...

Page 3: ... lines For proper operation and ap pearance of the dishwasher the cabinet opening should be square and have dimensions as shown in Figure 1 Ifthe dishwasheris to be installed in acor ner there must be sufficient clearance to open the door 2 minimum as shown in Figure 2 Rough in the water electrical and drain lines be f6repi ocee_ing with tlie installatio should run straight forward to their connec...

Page 4: ...to avoid injury 1 Remove frame strips on both sides of door panel see Figure 4 Flex insert panel out in middle to clear console panel Lift insert panel out of bottom frame Select desired color and reverse procedure to install Ifwhite is desired completely remove color panel and store for future use 2 Remove frame strip on one side of access panel Loosen but do not remove screws in other frame stri...

Page 5: ...factory set at the proper ten sion with insert panels installed If wood door pan els will be installed you will have to adjust the door spring tension Adjust by hooking the springs in a frame hole forward of the original setting see Fig ure 5 Door spring tension is correct when the door will remain horizontal in the full opened posi tion yet will rise to close with a slight lift of the fin ger Sid...

Page 6: ... a pro tective material e g electrical tape duct tape to avoid cutting the drain hose Local codes may require the drain line to be connected to house plumbing with a drain air gap If the drain hose is to be connected to a separate drain trap the trap must be vented with a drain air gap to prevent siphoning A drain loop must be fixed with a suitable clamp or support at a minimum height of 32 inches...

Page 7: ...n hose up to the inlet side of the air gap Continue drain line from outlet side of air gap down through floor to separate trap see Figure 8 sink at right Do not cut the corrugated drain hose Excess corrugated hose should be placed flat on the floor in the dishwasher cabinet Make sure the hose does not come into contact with any sharp edges Branch Pump Outlet Cut off here for 3 4 connection Large e...

Page 8: ...al Po er Supply The dishwasher operates on a 120 volt 60 Hz fused electrical supply Provide a separate circuit with a fuse or circuit breaker rated for at least 15 amps 20 amps if connected with disposer but not more than 20 amps DO NOT USE AN EXTENSION CORD Grounding Instructions This appliance must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must ...

Page 9: ... be grounded In the event of a malfunction or break down grounding will reduce the risk of electrical shock by providing a path of least resistance for electric current This appliance is equipped with a cord having an equipment cjrounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinanc...

Page 10: ... Use caution when moving this appliance to prevent damage to floor coverings andadjacent cabinets 1 As nearly as possible align the door front of the dishwasher with cabinet front top to bot tom 2 Make the space between the dishwasher and the cabinets the same on each side and the same from top to bottom NOTE Double check the levelers to make sure they set firmly against the floor Leveling is nec ...

Page 11: ...r reassembty 3 DRAIN HOSE 2 CLAMP DRAIN PORT 1 CHECK VALVE 4 PUMP HOUSING Push the valve 1 onto the pump housing 4 drain port making sure the letters reading TOP are located respectively This position locates the valve so that the slit end is perpendicular to the floor 2 Push the hose 3 and clamp 2 assembly over the drain outlet and valve Fasten the clamp securely 11 ...

Page 12: ...e valve freezes flooding may occur Connect Dishwasher to Electrical Supply The appliance MUST be permanently grounded in accordance with the National Electrical Code and local codes and ordinances WARNING Before making electrical connec tion disconnect power to fuse box or circuit breaker 1 Remove the junction box cover see Figure 13 2 Pull the house wiring in the cabinet area for ward to the junc...

Page 13: ... ing items Dishwasher level and securely fastened in place Water supply turned on Joints checked for leaks All wire connections tight Electricity turned on No kinks in water or drain lines o All packing material and customer literature taken out of the dishwasher Operate the machine through at least one fill and pump out o Check waier level Water should fill to the heat ing element Check for satis...

Page 14: ... drain hose is connected to a garbage disposer for the first time remember to knock out the plug in the disposer inlet This plug is inside the inlet You may not see the plug from the outside Refer to page 7 The dishwasher drain hose to the house drain must have a 32 inch loop above the floor or a suitable air gap must be used to prevent water from siphoning out of the dishwasher and causing washin...