Kenmore 580.72189 Owner'S Manual Download Page 1

Summary of Contents for 580.72189

Page 1: ...Owner s Manual Manual del Propietario ROOM AIR CONDITIONER ACONDICIONADOR DE AIRE DE VENTANA Model Modelo 580 72189 Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears com P N 3828A20133V ...

Page 2: ...ing according to instructions in this owner s manual Sears will repair this air conditioner free of charge if defective in material or workmanship FULL FIVE YEAR WARRANTY ON SEALED REFRIGERATION SYSTEM For five years from the date of purchase when this air conditioner is operated and maintained for normal room cooling according to instructions in this owner s manual Sears will repair the sealed re...

Page 3: ...three prong grounding plug for protection against shock hazards Your air conditioner must be plugged into in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with a protective covering This could result in ...

Page 4: ...ANSt NFPA 70 latest edition and all local codes and ordinances If a mating wall receptacle is not available it is the personal responsibility and obligation of the customer to have a properly grounded 3 prong wall receptacle installed by a qualified electrician Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord ...

Page 5: ...he carton is the best way to store unit during winter or when not in use To avoid risk of personal injury property damage or product damage due to the weight of this device and sharp edges that may be exposed Air conditioners covered in this manual pose an excessive weight hazard Two or more people are needed to move and install the unit To prevent injury or strain use proper lifting and carrying ...

Page 6: ... the side curtain ITEM A into the upper guide and lower guide of the air conditioner Fasten the curtains to the unit with screws ITEM E Lower Guide _ _ ITEM E FIG 6 _4J Open the window Mark a line on the center of the window inner sill Loosely attach the sill bracket ITEM C to the support bracket ITEM B using the carriage bolt ITEM I and the lock nut ITEM D ITEM B ITEM I r_ Attach the sill bracket...

Page 7: ...ITEM G See FIG 12 FIG 12 _11 DRAINAGE A drain hole is provided at the rear of the air conditioner unit Select a drain method according to the following Remove the hole rubber from the base pan Connect a drain elbow of 9 16 inside diameter to the drain pipe Connect a drain hose of 9 16 inside diameter to the drain elbow Drain hose is not supplied elbow Drain hose FIG 13 _ _ Slide the air conditione...

Page 8: ...20 1 1 2 rain WOODSTRIPMOUNTED 38ram ONTOPOF INNERSILL _ I I_ I_ 314 1 _ I CLEARANCE T STORM I v _ WINDOW INNER IL BRACKET L FRAME J J OUTER L_q l s LL INSIDE I I OUTSIDE FIG 20 REMOVAL FROM WINDOW Turn off and unplug the air conditioner Remove the front grille See HOW TO REMOVE THE FRONT GRILLE Refer to page 13 Unscrew the side screws that you installed in Step 15 Slide the air conditioner out of...

Page 9: ... if you hear a slight hissing or gurgling sound coming from your air conditioner after it is off These are normal coolant noises CAPACITY AND RUNNING TIME Proper unit size is important in deciding the desired comfort for the area you want to cool An undersized unit will not have the capability to cool leaving the area uncomfortably warm The proper size is determined by the number of square feet in...

Page 10: ...el 5 Adjust the louvers for comfortable air flow 6 Once the room has cooled adjust the TEMP and Mode Control to the setting you find most comfortable NOTE If the air conditioner is turned off wait 3 minutes before restarting This allows pressure inside the compressor to equalize Failure to wait 3 minutes before restarting may cause inefficient operation If you move the TEMP Control to a warmer the...

Page 11: ...s when the compressor stops cooling range of 60 F to 86 F by increments of I F Approximately every 3 minutes the fan will turn on and check the room air to determine if cooling is needed TIMER SHUT OFF TiME If unit is running Timer sets numberof hoursuntil shut off Everytime you push Timer button itadvances the Timersetting as follows 1 Hour 2 Hours 12Hours maximum START TIME If unit is off Timer ...

Page 12: ...me you want the unit to turn off automaticaIly For your speeping comfort once Timer is set the Temperature setting will raise by 2F after 30 min and 2F after another 30 min Every time you push this button the remaining time will be set as follows 1Hour 2Hours 3Hours 4Hours 5Hours 6Hours 7Hours OHours 1Hour 2Hours TIMER SHUT OFF TIME If unit is running Timer sets number of hours until shut off Ever...

Page 13: ...uring the Front Grille Push the grille up from the bottom and pull the top of the grille away from the case to lift the top tabs out of their slots AIR PURIFYING FILTER CLEANING _ CAUTION To avoid possibleminor electric shock do not touchAir PurifyingFilterwithin 10 secondsafteropeninginletgrille The Air Purifying filter behind the air filter should be checked and cleaned once every 3 months or mo...

Page 14: ...ight timecooling Todefrostthecoil setthe MODEto FANor HighCool withthe TEMPcontrol to hiqher temperature THEAIRCONDITIONER COOLING BUTROOM 18TOOWARM Check if Then Dirtyairfilter air restricted Cleanairfilter Referto Maintenancesectionof owner smanual TEMPControlset toowarm SetTEMP Controito lowertemperature Frontof unitis blockedbydrapes blinds furniture etc Ciearblockagein frontof unit Air distri...

Page 15: ... 15 ...

Page 16: ...oner To order Parts call Toll Free Model No 580 72189200 1 800 4 MY HOME S I 800 469 4663 CAUTION Use the Kenmore part number on all orders not the illustration number CABINET FRONT GRILLE ASSEMBLY 3 A 7 A 81A 12 01 16 ...

Page 17: ...ER DESCRIPTION NUMBER 1 A 3530A20045A FRONT GRILLE 2 A 3530A10102A INLET GRILLE 3 A 5231A20008A AIR FILTER ASSEMBLY 4 A 4758A30022A VAN E 5 A 4758A30023B LOUVER 6 A 4758A30023A LOUVER 7 A 3091AR6057F CABINET ASSEMBLY 8 A 2H00858E UPPER GUIDE 9 A 3850A20242R LABEL ENERGY 3828A20133V MANUAL OWNER S Functional Parts Non illustrated Parts 17 12 01 ...

Page 18: ...580 72189200 CAUTION Use the Kenmore part number on all orders not the illustration number CONTROL BOX ASSEMBLY 10 B 3 B 6 B 12 B 15 B 5 B 13 B 14 B 12 01 18 ...

Page 19: ... 6609A10003G 8 B 6411A20011K 9 B 6323A20004E 10 B 6631AR3843W 11 B 6850A90001G 12 B 6631A30003A 13 B 6601A30002A 14 B 6711A20053B 15 B 3790A20033B DESCRIPTION CONTROL BOX PANEL CONTROL COVER CONTROL BOX PWB ASSEMBLY AC PWB ASSEMBLY DC CAPACITOR H V ASSEMBLY POWER CORD ASSEMBLY THERMISTOR ASSEMBLY CONNECTOR ASSEMBLY FLAT CABLE WIRE ASSEMBLY SWITCH ASSEMBLY REMOTE CONTROL WINDOW DISPLAY Functional P...

Page 20: ...189200 CAUTION Use the Kenmore part number on all orders not the illustration number AIR HANDLING CYCLE PARTS 17 C 15 C 22 C 4 C 8 C 13 C 23 C 11 C 2 C 12 C 11 C 16 C 9 C 20 C 24 C 25 C 5 C 14 C 18 C 12 01 20 ...

Page 21: ...90A30016A BARRIER BLOCK 9 C 5901A20009A TURBO FAN 10 C 5901A20010A AXIAL FAN 11 C 3H02932C CLAMP SPRING 12 C 4998A10013A SH ROUD 13 C 4800A20001A BRACE 14 C 5421A20091A EVAPORATOR ASSEMBLY 15 C 5403A20062B CONDENSER ASSEMBLY 16 C 4948A30008A ORIFICE 17 C 3550A20089A COVER SHROUD 18 C 4H01029F WASHER RUBBER 19 C 3H02773A DRAIN PIPE 20 C 4H00261A PIPE ELBOW 21 C 4H02023A HOLE RUBBER 22 C 3530A20042D...

Page 22: ...580 72189200 CAUTION Use the Kenmore part number on all orders not the illustration number COMPRESSOR PARTS 8 D _ 9 D 12 D 7 D 13 D 6 D 5 D 2 D 4 D 3 D 1 D I 14 D 10 D 11 D 12 01 22 ...

Page 23: ...750U L025A 7 D 3550U L004A 8 D 4H01058A 9 D 4H00947A 10 D 5211A30066N 11 D 5211A20441A 12 D 5210A21099A 13 D 5210A21099B 14 D 5211AR3332Z DESCRIPTION ISOLATOR COMP COMPRESSOR BRACKET WASHER HEXAGON NUTS GASKET OVERLOAD PROTECTOR TERMINAL COVER GASKET NUT TERMINAL COVER NUT TUBE ASSEMBLY DISCHARGE TUBE ASSEMBLY SUCTION TUBE EVAPORATOR TUBE EVAPORATOR TUBE ASSEMBLY CONDENSER Functional Parts Non ill...

Page 24: ...580 72189200 CAUTION Use the Kenmore part number on all orders not the illustration number INSTALLATION KIT ASSEMBLY 12 01 24 ...

Page 25: ...SEMBLY ILLUSTRATION NUMBER 1 E 2 E 3 E 4 E 5 E 6 E 7 E 8 E PART NUMBER 4H01785B 4959AR3402E 4959AR3402F 3H01479D 3H01395C 4H01516A 4H01483A 4H01482A DESCRIPTION L BRACKET CURTAIN ASSEMBLY CURTAIN ASSEMBLY SUPPORT BRACKET SILL BRACKET LOCK NUT CARRIAGE BOLT M SCREW Functional Parts Non illustrated Parts 25 12 01 ...