background image

Summary of Contents for 580.71082

Page 1: ...Owner s Manual Manual del Propietario ROOM AIR CONDITIONER ACONDICIONADOR DE AIRE DE VENTANA Model Modelo 580 71082 Sears Roebuck and Co Hoffman Estates IL 60t_R_l www sears com ...

Page 2: ...tions in this owner s manual Sears will repair this air conditioner free of charge if defective in matedat or workmanship FULL FIVE YEAR WARRANTY ON SEALED REFRIGERATION SYSTEM For five years from the date of purchase when this air conditioner is operated and maintained for normal room cooling according to instruCtions in this owner s manual Sears will repair the sealed refrigeration system consis...

Page 3: ...nding plug for protection against shock hazards Your air conditioner must be plugged into in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with outside protective cover in place This could result in mech...

Page 4: ...o minimize possible shock hazard the cord must be plugged into a mating grounding type wall receptacle and grounded in accordance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances If a mating wall receptacle is not available it is the personal responsibility and obligation of the customer to have a properly grounded 3 prong wall receptacle installed b...

Page 5: ...L for future reference The carton is the best way to store unit during winter or when not in use INSTALLATION HARDWARE ITEM NAME OF PARTS A SIDE CURTAIN B SILL SUPPORT C BOLT D LOCK NUT E SCREW 25 64 F SCREW 5 8 G SCREW 5 8 H FOAM SEAL I FOAM STRIP J L BRACKET REQUIRED TOOLS FIG 2 i Q TY 2 2 2 2 13 3 5 1 1 1 To avoid risk of personal injury propertydamage or product damage due to the weightof this...

Page 6: ... the base pan handle and pull forward while bracing the cabinet FIG 4 _ i Cut the FOAM STRIP ITEM I to fit the underside of the window sash Peel off the backing and attach the FOAM STRIP as shown in Fig 5 FIG 5 L_ Insert the side curtain ITEM A into the upper guide and lower guide of the air conditioner Fasten the curtains to the unit with screws ITEM E ITEM E ITEM E FIG 6 _ _ Open the window Mark...

Page 7: ...rtain fully to each side of window opening Attach each side curtain to the window sash using screws ITEM G FIG 13 __ ITEM G _ FIG 13 _ Attach the L BRACKET ITEM J with screw ITEM G FIG 14 FIG 14 DRAINAGE Be sure to insert the drain pipe into base pan before installation The air conditioner must be installed with a slight tilt to the outside for proper water drainage The air conditioner will drain ...

Page 8: ...n in FiG 22 11 2 rain WOOD STRIPMOUNTED 38ram ONTOPOFINNER SILL 3 4 CLEARANCE _ INNER SILL STORM WINDOW FRAME OUTER SILL INSIDE OUTSIDE FIG 22 REMOVAL FROM WINDOW Turn off and unplug the air conditioner Remove the front grille See HOW TO REMOVE THE FRONT GRILLE Refer to page 13 Unscrew the side screws that you installed in Step 15 Slide the air conditioner out of the cabinet BE CAREFUL NOT TO DROP...

Page 9: ... sound coming from your air conditioner after it is off These are normal coolant noises i ompressor The modern high efficiency compressor may have a high pitched hum or pulsating noise that cycles on and off Unit Vibration The unit may vibrate and make noise because of poor wall or window construction You may hear droplets of water hitting the condenser causing a pinging or clicking sound Fan You ...

Page 10: ...ilure to wait 3 minutes before restarting may cause inefficient operation If you move the TEMP Control to a warmer then immediately back to a cooler setting the unit will shut off Wait 3 minutes before restarting 1 Cabinet 2 Vertical Air Direction Louver 3 Horizontal Air Direction Louver 4 Front Grille 5 Inlet Grille 6 Air Filter 7 Control Board 8 Power Cord 9 Evaporator 10 Condenser 11 Compressor...

Page 11: ...t the lowernumber for lower temperature of the room DISPLAY COOL FAN Everytime you push this button it will toggle betweenCOOL and FAN _ ON OFF TIMER SHUT OFF TIME If unit is running Timer setsnumber of hours untilshutoff Once Timer is set the Temperature setting will raise by 2 F after 30 rain and 2 F after another 30 rain Every time you push Timer button it advances the Timer setting as follows ...

Page 12: ...g Timer setsnumberofhours untilshut off OnceTimer is set the Temperaturesetting willraiseby2 F after30min and2 F after another30 min Everytime you pushTimer button itadvancestheTimersettingas follows 1 Hour 2Hours_ 3Hours_ etc START TIME Ifunit is off Timer sets numberof hoursbefore unitstarts Every time you pushTimer button it advancestheTimersetting as follows 1 Hour _2Hours _ 3Hours etc TIMER E...

Page 13: ...on The cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid appliance wax To ensure continued peak efficiency the condenser coils weather side at unit should be checked periodically and cleaned if they become clogged with soot or dirt from the atmosphere Brush or vacuum exterior coils to remove debris from fins FIG 30 HOW TO REMOVE THE FRONT GRILLE Open th...

Page 14: ...odefrost thecoil setthe MODEto FANor HighCool withthe TEMPoo_ to ahigher number THEAIR CONDITIONER COOLING BUTROOMISTOOWARM NOICEFORMING ONCOOUNGCOILBEHIND INLET GIRILLE Check if Dirtyairfilter air restricted TEMP Controlset toowarm Front of unitis blockedby drapes blinds furniture etc Air distributionis resthcted Doors windows registers etc open Cold airescapes Unitrecentlyturnedon inhot room The...

Page 15: ... 15 ...

Page 16: ...ner To order Parts call Toll Free Model No 580 71082100 1 800 4 MY HOME I 800 469 4663 CAUTION Use the Kenmore part number on all orders no___tt the illustration number CABINET FRONT GRILLE ASSY 3 A 2 A 4 A 5 A 01 01 16 ...

Page 17: ...POS NO PART NO DESCRIPTION 1 A 3530A10029A FRONT GRILLE 2 A 3530A10030A INLET GRILLE 3 A 5231A20004J AIR FILTER ASS Y 4 A 4758A20003A VANE 5 A 4758A30008A VANE 6 A 3091A30005J CABINET ASS Y 7 A 5210AR3196F UPPER GUIDE 8 A 3850A20046Y LABEL ENERGY 3828A20060M MANUAL OWNER S Functional Parts Non illustrated Parts 17 01 01 ...

Page 18: ...580 71082100 CAUTION Use the Kenmore part number on all orders not the illustration number CONTROL BOX ASS Y 11 B I 2 B 1 B 12 B 13 B 01 01 18 ...

Page 19: ... 6631AQ3201B 6 B 6120AR2359V 7 B 4H00442F 8 B 4994A10007A 9 B 3720A20053A 10 B 6871A20116K 11 B 6871A10013J 12 B 3550A30036B 13 B 6711A20035E DESCRIPTION POWER CORD ASS Y CLIP CORD CONNECTOR ASS Y THERMISTOR ASS Y WIRE ASS Y CAPACITOR CAPACITOR CLAMP CONTROL BOX PANEL CONTROL DISPLAY ASS Y PWB ASS Y MAIN COVER CONTROL BO REMOTE CONTROL Functional Parts Non illustrated Parts 19 01 01 ...

Page 20: ...580 71082100 CAUTION Use the Kenmore part number on all orders not the illustration number AIR HANDLING CYCLE PARTS 2 C 12 C I 19 C 11 C 13 C 8 C 10 C 18 C 15 C 1 16 C 01 01 20 ...

Page 21: ...ON DAMPER 5 C 4960A20002A MOTOR MOUNT 6 C 4681A20027B MOTOR ASS Y 7 C 3072A10001A SCROLL 8 C 5901A10005A FAN 9 C 5900AR1167B FAN 10 C 3H02932B CLAMP SPRING 11 C 4998A10001A SHROUD 12 C 4800A30001A BRACE 13 C 5421A20036C EVAPORATOR ASS Y 14 C 5403A20024C CONDENSER ASS Y 15 C 4H02023A DRAIN RUBBER 16 C 4H01029D WASHER RUBBER 17 C 3H02773A DRAIN PIPE 18 C 4790A10008A BARRIER 19 C 3530A20009B GRILLE A...

Page 22: ...580 71082100 CAUTION Use the Kenmore part number on all orders not the illustration number COMPRESSOR PARTS 4 8 D 7_o 6 D 5 D 2 D 4 D 3 D 1 D i 9 D 14 D 10 D 11 D 01 01 22 ...

Page 23: ... D 6750A30001A 7 D 3550A30048A 8 D 4H01058A 9 D 4H00947A 10 D 5210A20071A 11 D 5211A20130A 12 D 5211A20131A 13 D 5211AR3399A 14 D 5211A30260B ISOLATOR COMP COMPRESSOR BRACKET WASHER HEXAGON NUTS GASKET OVERLOAD PROTECTOR TERMINAL COVER GASKET NUT TERMINAL COVER NUT TUBE ASS Y DISCHARGE TUBE ASS Y SUCTION TUBE ASS Y EVAPORATOR TUBE ASS Y CONNECTOR TUBE ASS Y CAPILLARY Functional Parts Non illustrat...

Page 24: ...580 71082100 CAUTION Use the Kenmore part number on all orders no _jt the illustration number INSTALLATION KIT ASS Y J 2 E 01 01 24 ...

Page 25: ...tion number INSTALLATION KIT ASS Y POS NO PART NO DESCRIPTION 1 E 4959AR3402A SIDE CURTAIN ASS Y 2 E 4959AR3402B StDE CURTAIN ASS Y 3 E 4810AR3240A SILL SUPPORT BRACKET 4 E 1BHD1004006 BOLT 5 E 1NHC1000006 NUT 6 E 4H01785B L BRACKET Functional Parts Non illustrated Parts 25 01 01 ...