Kenmore 43813 Use & Care Manual Download Page 1

Range Hood

Use & Care Guide
Installation Manual

ENGLISH

V07820 rev. A                                 SEARS CANADA INC., Toronto, Ontario  M5B 2B8

www.sears.ca

Models

43813

(30” wide - Stainless)

43823

(36” wide - Stainless)

HB0057

Summary of Contents for 43813

Page 1: ...Range Hood Use Care Guide Installation Manual ENGLISH V07820 rev A SEARS CANADA INC Toronto Ontario M5B 2B8 www sears ca Models 43813 30 wide Stainless 43823 36 wide Stainless HB0057 ...

Page 2: ...unit 3 Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated The motor will restart when it cools down If the motor continues to shut off and restart have the hood serviced 4 For best capture of cooking impurities the bottom of the hood shouldbeaminimumof24 30 overagasrange andamaximum of 30 36 over a gas range above the cooking surface 5 Two i...

Page 3: ...erature level drops to normal the blower will return to its original setting OFF and LED over speed 3 will shut off 2 If blower is ON at a lower speed setting it turns blower up to HIGH speed and LED over speed 3 blinks rapidly When the temperature level drops to normal the blower will still be running on HIGH speed but the LED over speed 3 stops blinking and stay ON WARNING The HEAT SENTRY TM the...

Page 4: ...ver Robertson or Phillips Pencil Tape Measure Drill Sabre Saw Keyhole Saw or 3 8 Nutdriver Duct Tape Wire Stripper PARTS NOT INCLUDED WITH HOOD 120 V 50W MR 16 with GU10 base OR PAR 16 with GU10 base shielded halogen lamp 3 per 30 hood 4 per 36 hood Sears Part No V05921 Ducting Accessories See Range Hood System on page 5 for Ducting Accessory Model Nos Blower interior OR exterior See Range Hood Sy...

Page 5: ... 18 to 10 Rd vertical Broan Model 424 4 x 18 to 10 Rd Horiz front rear Broan Model 454 4 x 18 to 10 Rd Horiz Horiz right Broan Model 453 4 x 18 to 10 Rd Horiz Horiz left Sears Stock Number 32685 Blower Rough in Kit 600 cfm Interior Blower and Rough in Plate Optional Flue Extension Sears Stock Number 43805 43806 43807 Sears Stock Number 32674 Rough in Kit Use with Exterior Blower Model 32675 Sears ...

Page 6: ...10 round duct is attached for 1200 cfm blowers Use this chart to calculate the equivalent duct length of your system Note that 7 round is the minimum recommended duct size for 600 cfm blowers and 10 round is the minimum recommended duct size for 1200 cfm blowers Broan Model 410 Straight Duct 10 in round x 2 ft long Equivalent length 2 ft Broan Model 415 7 in Round Elbow Equivalent length 8 ft Broa...

Page 7: ...mm ROUND ELBOW 24 TO 30 609 to 762 mm ABOVE COOKING SURFACE WALL CAP HOOD OPTIONAL FLUE EXTENSION or SOFFIT HH0061A 10 254 mm ROUND DUCT ROOF CAP WALL CAP HOOD OPTIONAL FLUE EXTENSION or SOFFIT 4 x 18 to 10 114 x 470 to 254 mm ROUND TRANSITION see page 5 HH0062A 24 TO 30 609 to 762 mm ABOVE COOKING SURFACE EXTERIOR BLOWER EXTERIOR BLOWER HOOD OPTIONAL FLUE EXTENSION or SOFFIT HH0063A 24 TO 30 609 ...

Page 8: ...ll 2 Wood Mounting Strip 3 Flat Head Screw 4 Wall Anchor Location 5 Outline of the Back of the Hood 6 Wall Studs CAUTION Due to the weight of this hood ensure that the wood strip is attached to all of the available wall studs 2 studs minimum for the 30 hood more for a 36 hood not into drywall alone HD0169A 3 Using a Phillips 2 or a Robertson 2 screwdriver remove 4 screws retaining the pan to the h...

Page 9: ...y of the hood on the wood mounting strip CAUTION Hold the hood until it is completely secured to the wood mounting strip Secure hood to wood strip with 4 screws 8 provided at location shown Drill 2 3 16 size holes into the drywall for wall anchors through the existing holes in the inside hood back in the locations shown Then install the 2 wall anchors and attach the hood to these anchors with the ...

Page 10: ... with the soffit chimney Refer to page 5 for ordering information 1 To install blower refer to instructions included with blower rough in kit Once the blower is installed plug the blower unit into the female receptacle and the power supply onto the male connector inside the hood DO NOT plug the two cords into each other 2 Install the pan previously removed inside the hood and secure with its 4 scr...

Page 11: ... Replacement baffle filters are available Refer to page 12 for ordering information Warranty Safety Cleaning Operation Installation Service Parts HD0172 1 2 HD0173 1 Insert one end of baffle filter into the hood Push towards the front of the hood in order to insert the retaining clip into the baffle border slots 2 Raise lower end toward the inside of hood until it rest in its position ...

Page 12: ...1 1 8 V06138 Thermistor Heat Sentry 1 1 9 V03686 Filter Spring Clip 3 3 10 V16682 Baffle Filter 11 25 x 12 50 1 11 V16679 Baffle Filter 8 93 x 12 50 3 2 12 V16688 Inside Frame Ass y including item 9 30 x 18 x 24 1 V16693 Inside Frame Ass y including item 9 36 x 18 x 24 1 V07678 Harness Kit 1 1 V07820 Kenmore PRO Installation Manual 1 1 V12971 Installation Bag Flat head screws 10 x 2 4 Screws 8 x 8...

Reviews: