background image

Summary of Contents for 40752702

Page 1: ...so y Cuidado English EFpafiol Models Modelos 407 52702 l enmore0 Dehumidifier with xterna pump Deshurnidificador con bornba e terna Sears Brands Management Corporation Hoffman Estates IL 60179 U S A www sears com www kenmore com ...

Page 2: ...operation or maintenance 3 A service technician to clean or maintain this product 4 Damage to or failure of this product if it is not installed operated or maintained accord ing to the all instructions supplied with the product 5 Damage to or failure of this product resulting from accident abuse misuse or use for other than its intended purpose 6 Damage to or failure of this product caused by the ...

Page 3: ...thorized repair service Because the fan rotates at high speed dur ing operation always unplug dehumidifier before attempting any recommended main tenance or cleaning Do not block the inlet or outlet It may cause unit to fail or to operate inefficiently Do not remove plug from outlet by pulling on the cord When not in use turning the unit off will save energy Unplug the dehumidifier when not using ...

Page 4: ...hisappiiance must be grounded This appliancehas a power supply cord with a 3 prong grounded plug To minimize possible shock hazard the cord must be plugged into a matching grounded electrical out let that complies with the latestedition of the Nationat Electrical Codes and all local codes and ordinances If a grounded 3 prong electrical outlet is not available itis the personal responsi bility and ...

Page 5: ...in and lift bucket cover Remove pump hoses and hardware bag that contains the hose clamps PUmP screws and drainagej0int Eig 3 FRONT REAR CAUTION Please becarefulwhentakingout materials Do notdamagethe floatin the bucket Step 4 Insert front of bucket cover then rear Cover is secured when rear tabs snap in place To re install carry handle insert one side into handle bracket then slightly pull the ot...

Page 6: ...ier in the basemen t to help preveqt moisture damage i in the kitchen laundry room bath room and spalexercise areas that have excessive moisture to prevent moisture damage any where books or valuables are stored during construction or remodeling to reduce drying time for drywall and paint however check and clean filter often AUTOMATIC SHUT OFF When the bucket is full or when the bucket is not in t...

Page 7: ...Power Cord 10 ft Pump Drain Hose 3ft Dehumidifier Hose Vertical Pump Caster Dehumidifier Bucket Washable Filter Enclosure Control Panel Carry Handle Continuous Drain Connector Door Power Cord ...

Page 8: ...er indicator will light up when the timer key is pressed Press the timer key once more for a 4 hour delay start The 4 Hrs 7 timer indicator will now light up Press the timer key a third time to clear the timer setting No timer indica tors will light up when the timer setting is cleared AUTO SHUT OFF 4 Unit can be programmed to turn offat a desired time by pressing the Timer 4 key When the unit is ...

Page 9: ... the back Qfthe bucket withthe other hand Fig 2 3 Empty the bucket and replace the bucket in the dehumidifier Fig 3 NOTE Dehumidifier will not work when the BU CKET FULL indicator light is on or without the bucket properly placed in position Fig 2 Fig 3 OPTION 2 GRAVITY DRAIN HOSE INSTALLING THE DRAIN HOSE Step 1 Remove the bucket from the unit Fig 5 FIG 5 9 ...

Page 10: ...nector door Fig 6 i FIG S Step 3 Install and secure the draina Fig 7 Drainage Joint i le joint onto the drain connector i i FIG 7 Step 4 Place large hose clamp on the flat end of the dehumidifier drain hose Fig 8 s _Y FIG 8 10 ...

Page 11: ...nto the drainage joint so that it is fully seated Fig 9 _ri i il i FIG 9 Step 6 Secure hose by pushing large hose clamp towards the drainage joint Fig 10 FIG 10 Step 7 Place bucket inthe dehumidifier for operation Fig 11 FIG 11 11 ...

Page 12: ...on page 9 Step 2 For optimal operation it is recommended that the pump is placed on a flat and level location Attach the water pump to a wall or other perpendicular flat sur face with the included screws for security Fig 12 FIG 12 Step 3 Remove red cap from drain hose connector on pump Attach the small drain hose clamp onto the pump drain hose Fig 13 _ x _ i j J FIG 13 2 ...

Page 13: ...p connector until it is fully seated Fig 14 i J FIG 14 Step 5 Secure hose by pushing small clampforward towards the pump Fig 15 _ _ FIG t5 Step 6 Insert the angled end of the dehumidifierdrain hose into the water pump tank Fig 16 FIG 16 13 ...

Page 14: ...d pulling it toward you 2 Remove hose from drainage joint and cut hose to appropriate length 3 Once cut is completed refer to installing the Drain Hose to re install dehumidifier drain hose NOTE If the hose end that is intended for insertion into the pump is cut accidentally it must have an angled end for proper water draining USING THE DRAIN PUMP 1 Plug into grounded electrical outlet 2 Place the...

Page 15: ...and hold the FIL TER key up to 5 seconds on the con trol panel to reset the filter setting NOTE DO NOT place the filter in a dishwasher CAUTION DO NOT operate the dehu midifier without a filter Doing so may cause a unit failure _L WARNING Disconnect power supply cord from receptacle before performingany maintenance CLEANING THE EXTERIOR Clean the cabinetand outside of pump using a damp cloth and a...

Page 16: ... bucket must be in place and securely seated for the dehumidifier to operate There is a protective time delay up to 3 min to prevent trippingof the compressoroverload For this reason the unit may not start normal dehumidification for 3 min after it is powered back on When first installed allow at least24 hoursto achieve the desired humiditylevel Make sure there are no curtains blinds or furniture ...

Page 17: ... correctly Check the drain hose for kinks or obstructions Check the pump drain hose on the pump Is it installed correctly Check the pump drain hose for kinks or obstructions Solutions The capacityof your dehumidifier may not be adequate for the room size Close all doors and windowsto the outside This is normal Frost will usually dis appear within 60 minutes This is normal Wait approximately 3 minu...

Page 18: ...es 3 Wait 30 minutes before plug ging the dehumidifier back in for normal operation 4 If the Error is still indicated please contactyour nearest service center CatI 1 800 488 1222 for Service center locations ITEM 52702 MoistureRemovalper24 hours 70 Pintsperday 32 9Liters perday PowerConsumption W 765Watts Bucket Capacity 17Pints 8 Liters PowerSource 115V 160 HZ Rated Current Amps 7 3A Sound Press...

Page 19: ...Vertical Height Pumping 16 ft Power Source 115 V 60 HZ Rated Current Amps t2A Dehumidifier Drain Hose Inside Diameter 50 in t 13 mm Pump Drain Hose Inside Diameter 20 in 5 mm 9 ...

Page 20: ...st help by phone we call it Rapid Resolution phone support from a Sears representative on all products Think of us as a talking owner s man ual Power surge protection against electrical damage due to power fluctuations 250 Food Loss Protection annually for any food spoilage that is the result of mechanical failure of any covered refrigerator or freezer Rental reimbursement if repair of your covere...

Page 21: ...SPANISH SECTION 21 ...

Page 22: ...SPANISH SECTION 22 ...

Page 23: ...SPANISH SECTION 23 ...

Page 24: ...MY HOME _ 1_00 469 663 Call anytime day or night www se rs com Our Home For repair of carry initems like vacuums lawnequipment andelectronics call anytimeforthe locationofyour nearest Sears Parts Repair Service Center 1 800 488 1222 us A WWW SeaPs com To purchasea protectionagreement on a productservicedby Sears 1 800 827 6655 U SA Para pedir servido de reparation a domicilio y para ordenar piezas...

Reviews: