Kenmore 134199600H Installation Instructions Manual Download Page 3

3

GAS Dryer

CIRCUIT

 - Individual 15 amp. branch circuit fused with a 15

amp. maximum time delay fuse or circuit breaker.

POWER SUPPLY

 - 3 wire, 120 volt single phase, 60 Hz,

Alternating Current.

POWER SUPPLY CORD

 - The dryer is equipped with a 120 volt

3-wire power cord.

NEMA 10-30R

NEMA 14-30R

 

ELECTRICAL REQUIREMENTS

ELECTRIC Dryer

CIRCUIT

 - Individual 30 amp. branch circuit fused with 30

amp. time delay fuses or circuit breakers.

Use separately fused circuits for washers and dryers, and 

DO

NOT

 operate a washer and a dryer on the same circuit.

POWER SUPPLY

 - 3 wire or 4-wire, 240 volt, single phase, 60

Hz, Alternating Current.

POWER SUPPLY CORD KIT

 - 

3 wire

 - the dryer 

MUST

 employ

a 3-conductor power supply cord NEMA 10-30 type SRDT rated
at 240 volt AC minimum, 30 amp., with 3 open end spade lug
connectors with upturned ends or closed loop connectors and
marked for use with clothes dryers.  See ELECTRICAL
CONNECTIONS FOR A 3-WIRE SYSTEM.

4 wire

 - The dryer 

MUST

 employ a 4-conductor power supply

cord NEMA 14-30 type SRDT or ST (as required) rated at 240
volt AC minimum, 30 amp., with 4 open end spade lug
connectors with upturned ends or closed loop connectors and
marked for use with clothes dryers. See ELECTRICAL
CONNECTIONS FOR A 4-WIRE SYSTEM.
(Canada - 4-wire power supply cord is installed on dryer.)

WARNING – Risk of Shock.

  Appliance grounded to neutral

conductor through a link.  Grounding through the neutral link is
prohibited for (1) New branch circuit installations (2) mobile
homes; (3) recreational vehicles; and (4) areas where local codes
do not permit grounding through the neutral, (1) disconnect the
link from the neutral, (2) use grounding terminal or lead to
ground appliance in accordance with local codes and (3) connect
neutral terminal or lead to branch circuit neutral in usual manner
(if the appliance is to be connected by means of a cord kit, use
4-conductor cord for this purpose).  USE COPPER CONDUCTOR
ONLY.

OUTLET RECEPTACLE

 - NEMA 10-30R receptacle to be located

so the power supply cord is accessible when the dryer is in the
installed position. (Canada - NEMA 14-30R receptacle.)

NOTE: Do not under any
circumstances remove
grounding prong from
plug

.

GROUNDING PRONG

 

EXHAUST SYSTEM REQUIREMENTS

Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible

metal 

duct and approved vent hood which has a swing-out

damper(s) that open when the dryer is in operation. When the
dryer stops, the dampers automatically close to prevent drafts
and the entrance of insects and rodents. To avoid restricting the
outlet, maintain a minimum of 12 inches (30.5 cm) clearance
between the vent hood and the ground or any other obstruction.

 

The following are specific requirements for

proper and safe operation of your dryer. Failure to follow
these instructions can create excessive drying times and
fire hazards.

 

Do not install a clothes dryer with flexible

plastic venting materials.  

If your present system is made up

of plastic duct or metal foil duct, 

replace it

 with a rigid or semi-

rigid metal duct.  In Canada and the United States if metal (foil
type) duct is installed, it must be of a specific type identified by
the appliance manufacturer as suitable for use with clothes dryers
and in the United States must also comply with the Outline for
Clothes Dryer Transition Duct, UL standard 2158A.   Flexible
venting materials  are known to collapse, be easily crushed and
trap lint.  These conditions will obstruct clothes dryer airflow and
increase the

 risk of fire.  

  

Ensure the present duct is free of

any lint prior to installing dryer duct.

 

- Risk of Fire

 - 

A clothes dryer must be

exhausted outdoors

.  Do not exhaust dryer into  a chimney, a

wall, a ceiling, an attic, a crawl space or any concealed space
of a building.  A clothes dryer produces combustible lint.  If the
dryer is not exhausted outdoors, some fine lint will be expelled
into the laundry area. An accumulation of lint in any area of the
home can create a health and fire hazard. 

The dryer must be

connected to an exhaust outdoors.

  Regularly inspect the

outdoor exhaust opening and remove any accumulation of lint
around the outdoor exhaust opening and in the surrounding
area.

Summary of Contents for 134199600H

Page 1: ...Gas Electric Dryer Installation Instructions Secadora a gas y eléctrica Instrucciones para la instalación P N 134199600H 0804 Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears com ...

Page 2: ...followed to minimize the risk of fire or explosion or to prevent property damage personal injury or loss of life SAVE THESE INSTRUCTIONS Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Clear the room ...

Page 3: ...located so the power supply cord is accessible when the dryer is in the installed position Canada NEMA 14 30R receptacle NOTE Do not under any circumstances remove grounding prong from plug GROUNDING PRONG EXHAUST SYSTEM REQUIREMENTS Use only 4 inch 10 2 cm diameter minimum rigid or flexible metal duct and approved vent hood which has a swing out damper s that open when the dryer is in operation W...

Page 4: ...e floor Failure to do so can result in death explosion fire or burns 1 Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer 2 Set the dryer timer and temperature to air fluff cool down and start the dryer 3 Read the measurement on the manometer 4 The system back pressure MUST NOT be higher than 0 75 inches of water column If the system back pre...

Page 5: ...ance dimensions for proper operation in a recess or closet installation 5 A 1 8 inch 0 32 cm N P T plugged tapping accessible for test gauge connection MUST be installed immediately upstream of the gas supply connection to the dryer 6 The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1 2 psig ...

Page 6: ...5 cm 91 5 cm 91 5 cm ROUGH IN DIMENSIONS UNDER COUNTER STACK MODELS 2 54 cm 2 54 cm 2 54 cm 2 54 cm 2 54 cm REAR VIEW 36 36 36 36 36 91 5 cm 91 5 cm 91 5 cm 91 5 cm 91 5 cm 6 5 cm 6 5 cm 6 5 cm 6 5 cm 6 5 cm 9 5 cm 9 5 cm 9 5 cm 9 5 cm 9 5 cm ELECTRIC CONNECTION ELECTRIC CONNECTION ELECTRIC CONNECTION ELECTRIC CONNECTION ELECTRIC CONNECTION 13 1 2 13 1 2 13 1 2 13 1 2 13 1 2 34 4 cm 34 4 cm 34 4 c...

Page 7: ...ay be removed for installation 2 Return the dryer to an upright position PACKING FOAM SHIPPING REMOVE 4 SCREWS ONE FROM EACH HINGE FIRST MOBILE HOME INSTALLATION 1 Dryer MUST be exhausted outside outdoors not beneath the mobile home using metal ducting that will not support combustion Metal ducting must be 4 inches 10 16 cm in diameter with no obstructions Rigid metal duct is preferred 2 If dryer ...

Page 8: ...ly grounded For a grounded cord connected dryer 1 The dryer MUST be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electrical shock by a path of least resistance for electrical current 2 If your dryer is equipped with a power supply cord having an equipment grounding conductor and a grounding plug the plug MUST be plugged into an appropriate copper wired rece...

Page 9: ... 30 TYPE SRDT OR 30 AMP NEMA 14 30 TYPE SRDT OR 30 AMP NEMA 14 30 TYPE SRDT OR TYPICAL 4 CONDUCTOR STRAIN RELIEF MOUNTING BRACKET NUT TIGHTEN NUT TO THESE THREADS POWER CORD RED WHITE BLACK TERMINAL BLOCK SILVER TERMINAL GREEN GROUND SCREW GREEN POWERCORD GROUND WIRE NEUTRAL GROUND WIRE POWER CORD TIGHTEN NUT TO THESE THREADS NUT SILVER TERMINAL NEUTRAL GROUND WIRE GREEN GROUND SCREW STRAIN RELIEF...

Page 10: ...air 6 Run the dryer through a cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happens turn the timer to OFF and wait 5 minutes before making another attempt to light 7 If your drye...

Page 11: ... ESTAS INSTRUCCIONES Noalmaceneniutilicegasolinauotrosvaporesylíquidosinflamablesenlaproximidaddeésteodecualquierotroartefactoeléctrico QUEDEBEHACERSIPERCIBEOLORAGAS No trate de encender ningún artefacto eléctrico Notoqueningúninterruptoreléctrico nouseningúnteléfonoensuedificio Haga salir a todos los ocupantes de la habitación del edificio y del lugar Llame a su proveedor de gas desde el teléfono...

Page 12: ...os metálicos rígidos o flexibles de 4 10 2 cm de diámetro mínimo y una caperuza de salida de uso aprobado conregistrosquegirenhaciaafueraqueseabrencuando la secadora se encuentra en funcionamiento Cuando la secadora se detiene los registros se cierran automáticamente para evitar las corrientes de aire y la entrada de insectos y roedores Para evitar obstruirlasalida mantengaunaalturalibremínimade12...

Page 13: ...nectar su secadora a la línea de suministro de gas La tubería DEBE ser fabricada de acero inoxidable o cobre recubiertodeplástico 4 LatuberíadealimentacióndegasDEBEtenerunallavedecierre individual 5 Una toma de 1 8 de pulgada 0 32 cm N P T accesible para conexión del manómetro de prueba DEBE ser instalada inmediatamente aguas arriba de la conexión de la tubería de alimentación de gas a la secadora...

Page 14: ...persianada con aberturas para el aire en todo el largo de la puerta es aceptable DESPEJES MÍNIMOS DE INSTALACIÓN Pulgadas PARTE PARTE PARTE DELANTERA LADOS TRASERA SUPERIOR Alcoba o encastradas 0 0 cm 0 0 cm 0 0 cm 15 38 1 cm Armario 1 2 54 cm 0 0 cm 0 0 cm 15 38 1 cm Ventilación requirida en la puerta del armario dos aberturas rejilladas cada 60 pulg 2 387 cm2 3 7 6 cm desde la parte inferior y s...

Page 15: ...PARA VENTILACIÓN 68 6 cm 3 3 4 9 5 cm MODELOS DE DEBAJO DE MOSTRADOR Y APILADORES DIMENSIONES PARA LA INSTALACIÓN 68 6 cm 3 3 4 9 5 cm 4 3 8 11 1 cm 47 1 2 120 7 cm VISTA LATERAL PUERTA ABIERTA A 90 DISCO OPCIÓNAL REMOVIBLE PARA VENTILACIÓN MODELOS AUTÓNOMOS CON CONSOLA SUPERIOR DIMENSIONES PARA LA INSTALACIÓN CONEXIÓN ELÉCTRICA 1 2 54 cm CONEXIÓN DE LA TUBERÍA DE GAS DE 3 8 0 96 cm 2 9 16 6 5 cm ...

Page 16: ...l superior puede ser removido para la instalación 2 Vuelva la secadora a su posición vertical PLACA DE ESPUMA DE EMBARQUE EMPAQUE Correct Incorrect Incorrect NO Incorrect NO Correct Correct SI INSTALACIÓN EN CASAS MÓVILES 1 EltubodeescapedelasecadoraDEBEserinstaladohaciaelexterior Elescapedebecolocarseenlaparteexteriorynodebajodelacasa móvil Debeusarseductodemetalquenoseacombustible Elducto de met...

Page 17: ...el artefacto Para una secadora puesta a tierra con cordón eléctrico 1 La secadora DEBE ser puesta a tierra En caso de malfuncionamientoofalla lapuestaatierrareduciráelriesgo de choque eléctrico proporcionando un trayecto de menor resistencia a la corriente eléctrica 2 Sisusecadoraestáequipadaconuncordóneléctricoqueposee un conductor de puesta a tierra del equipo y un enchufe de puesta a tierra dic...

Page 18: ...RICO SOPORTE DE MONTAJEDEL ANCLAJEDE CABLE CORDÓNELÉCTRICO TUERCA ATORNILLE LA TUERCA EN ESTASROSCAS TORNILLO VERDEDE PUESTAA TIERRA CABLEDE PUESTA ATIERRA NEUTRAL BORNEPLATEADO CONEXIÓNES ELÉCTRICAS PARA UN SISTEMA TRIFILAR SecadorasELÉCTRICASNocanadienses 1 Saquelostornillosquesujetanlacubiertadeaccesodeltablero de bornes y el soporte de montaje del anclaje del cordón situadoenlaesquinasuperiord...

Page 19: ...ón 6 Haga funcionar la secadora durante un ciclo completo para comprobarsubuenfuncionamiento NOTA En las secadoras a gas antes de encender el quemador es necesario purgar el aire de la tubería del gas Sielquemadornoenciendedentrode45 segundos cuando la secadora se enciende por primera vez el interruptor de seguridad apagará el quemador Si ésto sucede gire el contador de tiempo a la posición OFF ap...

Page 20: ...__________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ___________...