Kendrion Kuhnke Automation GmbH
Mix 04 (694 444 64)
159
17 May 2021
0x2100 Enc1 Digital Interface Type
Object Code
Variable
Sub
0x00
Name
Enc1 Digital Interface Type
Data Type
UNSIGNED8
Access
rw
Defaultvalue
64
PDO Mapping
no
Accessname
Enc1DigitalInterfaceType
Settings of the connected encoder:
64 Encoder (default)
65 SSI
69 EnDat
80 Event counter
0x2101 Enc1 Digital Interface Control
Object Code
Variable
Sub
0x00
Name
Enc1 Digital Interface Control
Data Type
UNSIGNED16
Access
rw
Defaultvalue
0
PDO Mapping
optional, RPDO only
Accessname
Enc1DigitalInterfaceControl
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RC6
RC5
RC4
RC3
RC2
RC1
REF
REF
A rising edge starts the referencing
RC1…6 (Reset Event Counter 1...6
A rising edge resets the corresponding event counter
0x2102 Enc1 Digital Interface Status
Object Code
Variable
Sub
0x00
Name
Enc1 Digital Interface Status
Data Type
UNSIGNED16
Access
ro
Defaultvalue
PDO Mapping
optional, TPDO only