![Kemppi X5 FastMig Manual 400 Operating Manual Download Page 50](http://html1.mh-extra.com/html/kemppi/x5-fastmig-manual-400/x5-fastmig-manual-400_operating-manual_663367050.webp)
X5 FastMig
Operating manual - EN
2.11 Installing and replacing wire guide tubes
The wire feed mechanism includes three wire guide tubes. Replace them when the filler wire diameter grows or the
material changes.
When replacing the outlet guide tube, the welding gun must be detached.
a.
Inlet guide tube
b.
Middle guide tube
c.
Outlet guide tube
To replace the wire guide tubes:
1.
Release the pressure arms and remove the filler wire from the system.
2.
Pull out the inlet guide tube (a) and insert a new one in its place.
3.
Turn the locking clip aside to free the middle guide tube (b) for replacement.
4.
Insert a new middle guide tube in its slot and push it properly in place. Ensure that the mark arrow points to the
wire running direction.
5.
Turn locking clip back to lock down the new middle tube.
© Kemppi
51
1920960 / 2039
Summary of Contents for X5 FastMig Manual 400
Page 1: ...X5 FastMig Operating manual EN X5 FastMig Kemppi 2 1920960 2039...
Page 29: ...X5 FastMig Operating manual EN Kemppi 30 1920960 2039...
Page 36: ...X5 FastMig Operating manual EN 1 2 Kemppi 37 1920960 2039...
Page 108: ...X5 FastMig K ytt ohje FI X5 FastMig Kemppi 109 1920960 2039...
Page 136: ...X5 FastMig K ytt ohje FI Kemppi 137 1920960 2039...
Page 143: ...X5 FastMig K ytt ohje FI 1 2 Kemppi 144 1920960 2039...