16 – WELDFORCE KWF 200S / 0541
© KEMPPI OY
SETUP functions (6)
The unit is equipped with a number of additional functions, the selection and parameter value
settings for which are performed via the SETUP function.
The SETUP function is activated by pressing the SETUP button (6) for >1 second. The adjustable
parameter is selected via the left-hand potentiometer (2), the name of which is shown on display
No. 4. The value of the parameter in question is adjusted via the right-hand potentiometer (3), and
the value is shown on the display (5). The parameters and their possible values are:
The parameter’s value is immediately recorded in the memory. Exit SETUP mode by holding down
the new SETUP button or by briefly pressing the ON/OFF button.
Weld data (13)
The weld data function is activated by pressing buttons 8 and 9 simultaneously. The weld data
function returns the welding current and voltage values that were in use when welding was
discontinued to the displays.
MMA (14)
Selection of MMA welding is activated by pressing buttons 6 and 7 simultaneously. To get back
to MIG welding repress buttons 6 and 7.
Use of remote control units (10)
When a remote control unit is connected to the device, LED (10) lights up and the wire feed speed
and welding voltage setting operations are performed via remote control. In this case, potentiometers
2 and 3 of the panel are disconnected.
Name of
parameter
Name
on
display
Parameter
values
Factory
setting
Description
Creep Start
CrE
10 … 170 %
50 %
Percentage of wire feed
speed:
10 % = slowed start
170 % = accelerated start
Post Current
PoC
-9 … +9
0
Post current
Selection of Wire
Feeder Address
Add
85 or 90
85
Bus address of wire feeder
Maximum
Wire Feed Speed
FS
18 or 25 m/min
(709 or 984 ipm)
18 m/min
(709 ipm)
The max. wire feed speed
selected; dependent on
feed wheels
Disable PMT MIG
guns
Gun
OFF or ON
ON
OFF = other gun
ON = PMT gun
Restore Factory
Settings
FAC
OFF or ON
OFF
Restores factory settings
when ‘ON’ is selected.