Control card A001 jumper functions

Factory setting

13

Recalls the EEPROM parameter´s factory
settings. Flash-memory update in
malfunction situations

13

X13

Factory setting. Enables the flas-memory
programming in production. Must remain
closed!

14

X14

23

X23

Factory setting.
Flash-memory block
1 in use.

23

Flash-memory block 2 in use.

H1 LED

FANS,

 LED is on, when fans aren´t rotating and vice versa. If fans never rotate,

check the fan supply voltage from connector X, between pins 3 - 8 and 6 - 9 (24 VDC).

H2 LED

BUS POWER SUPPLY

, while the LED is on, it indicates th e50 VDC voltage

present in the bus connection. If the LED is off, then check the voltage from connector X4
between pins 6 - 8. Check the fuse F002, diode bridge G004 and auxiliary transformer
T002.

H3 LED

SERIAL COMMUNICATION

, while the LED is on, it indicates the presence of

serial communication. If the H2 is on, but H3 is off, most likely there is something wrong
with the program on the control card.

H4 LED

: REMOTE CONTROLLER, while the LED is on, it indicates a connected remote

controller R10 or R20.

H5 LED

:

 GATE PULSES

, while the LED is on, it indicates the presence of the gate pulses.

LED´s brightness depends on pulse width and the power under load.

H6 LED

X5- AND X6-CONNECTORS ARE CROSS-CONNECTED, 

while on, the LED

indicates the cross-connection of IGBT gate connectors X5 and X6. Shut the machine down
and connect the gates correctly!

H7/H8

GATE PULSES:

 while on, the LEDs indicate the presence of gate pulses. Brightness

of the LEDs depends on pulse width. If H5 is on, but H67 and H8 are off, then the gate
circuit is damaged (pulse transformer, FETs etc..

Control card A001 LEDs

12

Summary of Contents for WELDFORCE KPS 3500

Page 1: ...Service manual Ver 1 0...

Page 2: ...components 5 8 Control cable connectors 9 Troubleshooting diagram 10 Control card A001 layout 11 Control card A001 jumper 11 12 Control card A001 leds 12 IGBT gate pulse 13 Voltage over the lower IGB...

Page 3: ...V 300 A 46 V 400 A 50 V 500 A OCV appr 65 V appr 65 V Appr 65 V Idling power 75 W 75 W 75 W Efficiency on nominal values Appr 85 appr 85 appr 85 Power factor on nominal values appr 0 93 appr 0 93 appr...

Page 4: ...source s power stage is a traditional half bridge where the intermediate circuit DC voltage is halved by working capacitors C2 and C3 IGBT transistors work as power switches When both IGBTs are non co...

Page 5: ...pens the electromagnetic disturbances conducting to the net EMI Varistors 550 V form an overvoltage protection against low energy voltage spikes Note Filter card Z004 and varistors are mounted before...

Page 6: ...t voltage The primary choke L001 limits the in rush current during switching and filters the DC voltage together with the smoothing capacitors Smoothing capacitors 2 x 25 F 700 VDC Work capacitors 350...

Page 7: ...the main transformer T001 Inverter s power adjustment is based on pulse width modulation PWM RC protections ease the stress on the semiconductors KEMPPI WELDFORCETM 5500 The chokes LL301 and LL302 of...

Page 8: ...ened by secondary choke L002 The secondary circuit current is measured by a shunt resistor The shunt s voltage is amplified by shunt amplifier A001 2 and taken to control card A001 s PWM adjuster Cont...

Page 9: ...e connectors X006 and X007 The cooling unit KWU 10 is connected to connectors X010 and X011 KPS 4500 KPS 5500 The control card A001 is similar in all Kemppi WELDFORCETM power sources The machine size...

Page 10: ...s switched on A faulty primary circuit semiconductor Check the semiconductors on the primary side The power source doesn t reach maximum power The net fuses has blown A faulty supply cable A faulty pr...

Page 11: ...ng X7 1 5 6 1 MIG wire feeder is other than KWF MIG wire feeder is KWF 2 2 Scratch TIG enabled Scratch TIG disabled 3 3 OCV is approx 65 V OCV approx 16 V VRD 4 4 Not in use Factory setting 5 Not in u...

Page 12: ...04 and auxiliary transformer T002 H3 LED SERIAL COMMUNICATION while the LED is on it indicates the presence of serial communication If the H2 is on but H3 is off most likely there is something wrong w...

Page 13: ...IGBT gate pulse a a The gate pulse on values 10A 14 5V MIG meas point a 10V 20 s DIV a The gate pulse on values 450A 36 5V MIG meas point a 10V 20 s DIV a Control cardi A001 13...

Page 14: ...Voltage over the lower IGBT b Voltage over the lower IGBT on values 10A 14 5V MIG meas point b 100V 20 s DIV b b Voltage over the lower IGBT on values 450A 36 5V MIG meas point b 100V 20 s DIV 14...

Page 15: ...he secondary diode cards c Voltage after the secondary diode cards on values 10A 14 5V MIG measuring point c 20V 20 s DIV c c Voltage after the diode cards on values 450A 36 5V MIG measuring point c 2...

Page 16: ...c Voltage on connector X010 between pins 2 6 measuring point d a Pump motor ON b Pump motor OFF c Pump motor continous run selected e e e e a b c Voltage on connector X010 between pins 1 6 measuring...

Page 17: ...pacitors Working capacitors Secondary unit Diode card Fans Main transformer T001 Shunt resistor R001 Auxiliary transformer T002 Control card A001 Filter Structure Filter card Z003 Commutation unit L00...

Page 18: ...Notes...

Reviews: