R164
Inverter frequency
Control card A001 layout
Control card A001 jumper functions
X4
X9
X1
X2
X5
X6
H1
H4
H3
H5
H6
H7
H8
X14
X13
X23
X2
2
X21
X20
H2
R164
X12
X11
X10
5 6 7
X7
7
6
5
Factory setting
X7
1
5
6
1
MIG, wire feeder is other
than KWF
MIG, wire feeder is KWF
2
2
Scratch-TIG enabled
Scratch-TIG disabled
3
3
OCV is approx. + 65 V
OCV approx.. + 16 V
(VRD)
4
4
Not in use
Factory setting
5
Not in use
Factory setting
6
If the arc is not lit in 2
seconds, the inverter is
stopped.(MIG)
If the arc is not lit in 2 seconds, the inverter &
wire feeding are stopped.(MIG)
7
7
Not in use
Factory setting
11