TROUBLESHOOTING FOR PRO COOLING UNIT
GENERAL MAINTENANCE OF PROCOOL 10
The amount of use and the working enviroment should be taken into consideration when
planning the frequency of maintenance. Careful use and preventive maintenance will
help to ensure trouble-free operation.
CHECK DAILY!
-
amount of cooling liquid
(NOTE! If cooling liquid has boiled, it must be
replaced, because then the solution has lost its metal coats protective effect.)
- check with test switch that liquid is also returned to reservoir.
-
gaskets of welding/liquid cables.
DON´T USE LEAKING WELDING CABLES OR
HOSES.
- condition of connection cables.
The number of systems in operation and the importance of minimize not running time
will determine to what extend consumable- and spare parts will be stocked.
TROUBLESHOOTING CHART
TROUBLE
CAUSE
REMEDY
Indicator lamp H002 is
swicthed on. Pump does not
work, motor does not rotate.
Faulty pumpr, motor does not
rotate or PROCOOL is out of
liquid.
Liquid leakage in cooling
system.
See check point picture.
Repair the pump/pumpmotor
or add cooling liquid.
Repair/change leaking liquid
hose.
Follow the the check point
instructions.
Indicator lamp H001 is swit-
ched on. Liquid circulation
continues.
Cooling liquid is overheated.
Wait until cooling liquid and
PTC is cooled.
MIG/TIG unit stops welding,
liquid circulation continues.
Control cable broke
during
welding
.
Bad connection in control
cables.
Check that control cables are
properly tightened.
Check all wires with
multimeter that they are not
cut.
See picture of connector
and cable.
MIG/TIG welding can not be
started.
Control cable broke
when
welding is not going on.
Bad connection in control
cables.
Check that control cables are
properly tightened.
Check all wires with
multimeter that they are not
cut.
See picture of connector
and cable.