Power source overheat indicator light is lit.
Power source is overheated.
•
Check that there is enough free space behind the machine for cooling air circula-
tion.
•
Check cooling unit for water circulation, clean cooling unit filter and air grate. Add
cooling liquid if necessary.
For further information and assistance, contact your nearest Kemppi service workshop.
4.3. DISPOSAL OF THE MACHINE
Kemppi machines are produced mainly of recyclable materials. Please deliver an old machine
to be removed from service to a treatment plant where it is possible to separate the materials for
recycling.
4.2. ORDERING NUMBERS
Master 2500 MLS
6104250
Master 2503 MLS
6102250
Welding cable 35mm², 2,5 m
6184301
Earth cable 25mm², 2,5 m
6184311
Electric plug 16 A, 5-poles
9770812
Master 3500 MLS
6104350
Master 3503 MLS
6102350
Welding cable 50mm², 2,5 m
6184501
Earth cable 50mm², 2,5 m
6184511
Electric plug 16 A, 5-poles
9770812
Mastertig 2500 MLS
6114250
Mastertig 2503 MLS
6112250
Torches
TTC 160 4m
627016004
TTC 160 8m
627016008
TTC 160 16m
627016016
TTC 220 4m
627022004
TTC 220 8m
627022008
TTC 220 16m
627022016
Earth cable 35mm², 5 m
6184311
Electric plug 16 A, 5-poles
9770812
Gas flow meter AR/clock
6265136
Mastertig 3500 MLS
6114350
Mastertig 3503 MLS
6112350
Torches
TTC 160 4m
627016004
TTC 160 8m
627016008
TTC 160 16m
627016016