Kempact™ pulse 800 mVu automotiVe / 0709 – 1
© Kemppi oy
Changing parameters
By pressing the (SETUP) selection switch a little longer the machine will enter the SETUP state.
The display will show the set parameter’s runnning number (blinking), its abbreviation and value.
Select the parameter number using the “SYNERGIC PRG” + and - buttons or the “SETUP” button
(which will jump by tens). Change the value using the control button (in some cases, the value
can be found from the synergy curve). “Syn” and the curve value will blink by turns on the right
of the display. Set the value by turning the button anticlockwise.
Exit for SETUP using a long press.
3.3.11. Error codes
Error codes are among others the following:
Err 3: Overvoltages in the mains supply. Also the pilot light of overvoltage is lighting.
Err 4: The thermal protection of power suorce has stopped welding. Also the pilot light of
thermal protection is lighting.
Err 6: The terminal voltage has rised. Take the device to service.
Err 153: Liquid cooled PMT- or WS-gun is overheated. Or torch-PTC or RMT10 has beeb installed,
but the jumber inside the torch is in FU-position, look also instruction of torch.
Err 154: Overloading of the wire feed motor
Error code is eliminated when the reason is aborted, except Err 6, which demands to turn down
the machine.
4. MAINTENANCE
4.1. DAILY MAINTENANCE
Be careful of mains voltage when handling electric cables!
Clean the wire channel of the gun and check the contact tip regularly. Always check the condition
of the mains and welding cable before operation and replace defective cables.
Note! Only a qualified electrician should remove or install the mains cable!
4.2. REGULAR MAINTENANCE
KEMPPI -service workshops sign special service contracts with customers for regular maintenance.
All parts are cleaned, checked and if necessary, repaired. The operation of the welding machine
is also tested.
4.3. DISPOSAL OF THE MACHINE
Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic
Equipment and its implementation in accordance with national law, electrical equipment
that has reached the end of its life must be collected separately and returned to an
environmentally compatible recycling facility. As the owner of the equipment, you should
get information on approved collection systems from our local representative.
By applying this European Directive you will improve the environment and human
health!