Kemppi HiArc S 140 Operating Manual Download Page 9

9

© Kemppi Oy / 1418  

EN

9

3. 

use

NOTE!  

It is forbidden to weld in places where there is a danger of fire or 

explosion!

3.1 

Welding processes

3.1.1  manual metal arc welding (mma)

In manual metal arc welding (MMA) the welding filler material is melted 

from the electrode to the weld pool. The rate of the welding current is 

selected based on the electrode size used and the welding position. Arc 

forms between electrode tip and welding piece. The melting electrode 

coating forms gas and slag, which protects the weld pool. Slag solidified 

over the weld is removed after welding e.g. with a chipping hammer (use of 

eye protection is strongly advised).

3.1.2  tig welding

In DC TIG welding, the arc between the tungsten electrode and the welding 

piece melts the welding piece, thus forming a weld pool. Arc and electrode 

are shielded by an inert shielding gas (argon). If necessary, filler is used. Filler 

wire is fed into the weld pool from the outside of the arc. The filler wire and 

the welding current level are decided according to the base material type 

and thickness, joint form and welding position.

Summary of Contents for HiArc S 140

Page 1: ...Operating manual Manual de instrucciones Manuel d utilisation Manual de utiliza o EN ES FR PT RU HiArc S 140...

Page 2: ......

Page 3: ...Kemppi Oy 1418 Operating manual English...

Page 4: ...8 3 Use 9 3 1 Welding processes 9 3 1 1 Manual Metal Arc welding MMA 9 3 1 2 TIG welding 9 3 2 Operating functions 10 3 3 Welding selections 11 3 3 1 Manual Metal Arc welding MMA 11 3 3 2 DC TIG weld...

Page 5: ...hange without prior notice Important notes Items in the manual that require particular attention in order to minimise damage and personal harm are indicated with the NOTE notation Read these sections...

Page 6: ...ir circulates freely Serial number Serial number of the unit is marked on the rating plate of the unit The serial number makes it possible to trace product manufacturing series You might need the seri...

Page 7: ...supply cord its cross sectional area should be at least as large as the supply voltage cable fitted to the machine The maximum length for the extension cable is 50 m The minimum power of a single pha...

Page 8: ...ressure side of the cylinder regulator or flow meter and tighten the connector 2 Adjust the shielding gas flow rate with the flow regulation adjustment screw A suitable gas flow rate is 8 15 l min 3 C...

Page 9: ...ng electrode coating forms gas and slag which protects the weld pool Slag solidified over the weld is removed after welding e g with a chipping hammer use of eye protection is strongly advised 3 1 2 T...

Page 10: ...ght is always on when the unit is connected to the mains and the main switch is in position I NOTE Always start and stop the machine from the main switch never use the plug as a switch Welding process...

Page 11: ...or arc welding Protect yourself and your surroundings from the arc and hot spatter 3 4 1 Earthing If possible always fix earth return cable clamp directly on the welding piece 1 Clean connection surfa...

Page 12: ...ly made wall rack or cylinder trolley Always close the cylinder valve after having finished welding 3 5 Storing Store the unit in a clean and dry place Shield it from rain and in temperatures exceedin...

Page 13: ...hine s duty cycle has been exceeded wait for indicator to turn off Too low or high supply voltage If the machine s malfunction is not eliminated with these measures contact KEMPPI service 4 3 Disposal...

Page 14: ...140 EN 14 5 Ordering numbers Item Ordering number HiArc S 140 6302140 Earth return cable and clamp 6184015 Welding cable and electrode holder 6184005 Carrying strap 9592162 Optional TIG torchTTM15V 4...

Page 15: ...layed 16 A Welding range MMA 10 A 20 5V 140 A 25 6V TIG 5 A 10V 150 A 16V Welding current control stepless Open circuit voltage 85V Idle power 10W Power factor at 100 ED 0 60 Efficiency at 100 ED 80 S...

Page 16: ...D 35428 Langg ns DEUTSCHLAND Tel 49 6 403 7792 0 Telefax 49 6 403 779 79 74 sales de kemppi com KEMPPI SP KA Z O O Ul Borzymowska 32 03 565WARSZAWA POLAND Tel 48 22 7816162 Telefax 48 22 7816505 info...