Kemppi HiArc S 140 Operating Manual Download Page 8

8

Hiarc S 140

EN

8

shielding gas

In TIG welding, shielding gas is used to prevent atmospheric contamination 

of the molten weld pool and cooling weld. Normally, the shielding gas 

is argon (Ar). Normally the gas flow rate is approximately 8–15 litres per 

minute, but this can vary according to the welding current used and the size 

of gas nozzle.
Connect the TTM 15V TIG torch gas hose to the outlet of the regulator. 

NOTE!  

Under no circumstances should you connect the hose directly to 

the cylinder valve. Always use a regulator and flow meter for safe and 

accurate operation.

1. 

Connect the hose to the reduced pressure side of the cylinder 

regulator, or flow meter and tighten the connector.

2. 

Adjust the shielding gas flow rate with the flow regulation adjustment 

screw. A suitable gas flow rate is 8–15 l/min

3. 

Close the cylinder valve after use.

2.4 

filler materials and equipment

See also 2.1 Main components. You can use all electrodes intended for 

welding with DC. Suitable electrode sizes for the unit are listed in the end of 

these instructions in Technical data.

1. 

Use welding specifications given on electrode package.

2. 

Check that you have selected the correct welding process before 

starting to weld.

3. 

Check that welding cable and earth return cable connections are tight. 

If a connection is slack, it will result in voltage drop that will cause the 

connection to heat.

4. 

Mount the electrode firmly in holder.

Summary of Contents for HiArc S 140

Page 1: ...Operating manual Manual de instrucciones Manuel d utilisation Manual de utiliza o EN ES FR PT RU HiArc S 140...

Page 2: ......

Page 3: ...Kemppi Oy 1418 Operating manual English...

Page 4: ...8 3 Use 9 3 1 Welding processes 9 3 1 1 Manual Metal Arc welding MMA 9 3 1 2 TIG welding 9 3 2 Operating functions 10 3 3 Welding selections 11 3 3 1 Manual Metal Arc welding MMA 11 3 3 2 DC TIG weld...

Page 5: ...hange without prior notice Important notes Items in the manual that require particular attention in order to minimise damage and personal harm are indicated with the NOTE notation Read these sections...

Page 6: ...ir circulates freely Serial number Serial number of the unit is marked on the rating plate of the unit The serial number makes it possible to trace product manufacturing series You might need the seri...

Page 7: ...supply cord its cross sectional area should be at least as large as the supply voltage cable fitted to the machine The maximum length for the extension cable is 50 m The minimum power of a single pha...

Page 8: ...ressure side of the cylinder regulator or flow meter and tighten the connector 2 Adjust the shielding gas flow rate with the flow regulation adjustment screw A suitable gas flow rate is 8 15 l min 3 C...

Page 9: ...ng electrode coating forms gas and slag which protects the weld pool Slag solidified over the weld is removed after welding e g with a chipping hammer use of eye protection is strongly advised 3 1 2 T...

Page 10: ...ght is always on when the unit is connected to the mains and the main switch is in position I NOTE Always start and stop the machine from the main switch never use the plug as a switch Welding process...

Page 11: ...or arc welding Protect yourself and your surroundings from the arc and hot spatter 3 4 1 Earthing If possible always fix earth return cable clamp directly on the welding piece 1 Clean connection surfa...

Page 12: ...ly made wall rack or cylinder trolley Always close the cylinder valve after having finished welding 3 5 Storing Store the unit in a clean and dry place Shield it from rain and in temperatures exceedin...

Page 13: ...hine s duty cycle has been exceeded wait for indicator to turn off Too low or high supply voltage If the machine s malfunction is not eliminated with these measures contact KEMPPI service 4 3 Disposal...

Page 14: ...140 EN 14 5 Ordering numbers Item Ordering number HiArc S 140 6302140 Earth return cable and clamp 6184015 Welding cable and electrode holder 6184005 Carrying strap 9592162 Optional TIG torchTTM15V 4...

Page 15: ...layed 16 A Welding range MMA 10 A 20 5V 140 A 25 6V TIG 5 A 10V 150 A 16V Welding current control stepless Open circuit voltage 85V Idle power 10W Power factor at 100 ED 0 60 Efficiency at 100 ED 80 S...

Page 16: ...D 35428 Langg ns DEUTSCHLAND Tel 49 6 403 7792 0 Telefax 49 6 403 779 79 74 sales de kemppi com KEMPPI SP KA Z O O Ul Borzymowska 32 03 565WARSZAWA POLAND Tel 48 22 7816162 Telefax 48 22 7816505 info...