Kemppi HiArc S 140 Operating Manual Download Page 13

13

© Kemppi Oy / 1418  

EN

13

4.2 

troubleshooting

Problem

Cause

The main switch indicator will 

not light up

No electricity connected to the machine

•  Check the mains supply fuses.
•  Check the mains cable and plug.

Poor welding result

Several factors affect the welding quality. 
•  Check that the earthing clamp is firmly attached, the point 

of attachment is clean and that the cable and its connectors 
are intact.

•  Check that the shielding gas flows out of the torch tip.
•  Check that the electric voltage is not irregular or too low/

high.

Overheating indicator lit

The device has overheated.
•  Ensure that cooling air has unrestricted flow.
•  If the machine’s duty cycle has been exceeded, wait for 

indicator to turn off.

•  Too low or high supply voltage.

If the machine’s malfunction is not eliminated with these measures, contact 

KEMPPI service.

4.3 

Disposal

Do not dispose of electrical equipment with normal waste!
In observance of European Directive 2002/96/EC on waste electrical 

and electronic equipment, and its implementation in accordance with 

national law, electrical equipment that has reached the end of its life must 

be collected separately and taken to an appropriate environmentally 

responsible recycling facility. 
The owner of the equipment is obliged to deliver a decommissioned unit 

to a regional collection centre, per the instructions of local authorities 

or a Kemppi representative. By applying this European Directive you will 

improve the environment and human health.

Summary of Contents for HiArc S 140

Page 1: ...Operating manual Manual de instrucciones Manuel d utilisation Manual de utiliza o EN ES FR PT RU HiArc S 140...

Page 2: ......

Page 3: ...Kemppi Oy 1418 Operating manual English...

Page 4: ...8 3 Use 9 3 1 Welding processes 9 3 1 1 Manual Metal Arc welding MMA 9 3 1 2 TIG welding 9 3 2 Operating functions 10 3 3 Welding selections 11 3 3 1 Manual Metal Arc welding MMA 11 3 3 2 DC TIG weld...

Page 5: ...hange without prior notice Important notes Items in the manual that require particular attention in order to minimise damage and personal harm are indicated with the NOTE notation Read these sections...

Page 6: ...ir circulates freely Serial number Serial number of the unit is marked on the rating plate of the unit The serial number makes it possible to trace product manufacturing series You might need the seri...

Page 7: ...supply cord its cross sectional area should be at least as large as the supply voltage cable fitted to the machine The maximum length for the extension cable is 50 m The minimum power of a single pha...

Page 8: ...ressure side of the cylinder regulator or flow meter and tighten the connector 2 Adjust the shielding gas flow rate with the flow regulation adjustment screw A suitable gas flow rate is 8 15 l min 3 C...

Page 9: ...ng electrode coating forms gas and slag which protects the weld pool Slag solidified over the weld is removed after welding e g with a chipping hammer use of eye protection is strongly advised 3 1 2 T...

Page 10: ...ght is always on when the unit is connected to the mains and the main switch is in position I NOTE Always start and stop the machine from the main switch never use the plug as a switch Welding process...

Page 11: ...or arc welding Protect yourself and your surroundings from the arc and hot spatter 3 4 1 Earthing If possible always fix earth return cable clamp directly on the welding piece 1 Clean connection surfa...

Page 12: ...ly made wall rack or cylinder trolley Always close the cylinder valve after having finished welding 3 5 Storing Store the unit in a clean and dry place Shield it from rain and in temperatures exceedin...

Page 13: ...hine s duty cycle has been exceeded wait for indicator to turn off Too low or high supply voltage If the machine s malfunction is not eliminated with these measures contact KEMPPI service 4 3 Disposal...

Page 14: ...140 EN 14 5 Ordering numbers Item Ordering number HiArc S 140 6302140 Earth return cable and clamp 6184015 Welding cable and electrode holder 6184005 Carrying strap 9592162 Optional TIG torchTTM15V 4...

Page 15: ...layed 16 A Welding range MMA 10 A 20 5V 140 A 25 6V TIG 5 A 10V 150 A 16V Welding current control stepless Open circuit voltage 85V Idle power 10W Power factor at 100 ED 0 60 Efficiency at 100 ED 80 S...

Page 16: ...D 35428 Langg ns DEUTSCHLAND Tel 49 6 403 7792 0 Telefax 49 6 403 779 79 74 sales de kemppi com KEMPPI SP KA Z O O Ul Borzymowska 32 03 565WARSZAWA POLAND Tel 48 22 7816162 Telefax 48 22 7816505 info...

Reviews: