3.8.16 Copying/transferring files to memory stick
(*These are the actual weld programs, not print files. They
are special file types formatted for the welding control
system, not human-readable files.)
1. To transfer a weld program from internal memory
to a memory stick or vice versa, place the stick in
the USB port on the front of the power source.
The stick will require approximately 1 minute to
initialize, during which time the LCD on the side
of the key will slowly pulse. When it is ready, it will
blink rapidly 5 times.
2. In the Maintenance Menu, select
Copy Welds
and
press
Enter
. Enter the desired program numbers
for source weld and destination weld, then press
Copy
. For weld programs 100 and above, indicate
a program to be stored (or presently stored) on the
stick.
When performing a copy or transfer to a destination
program of the same number, the new file does not write
over the existing file. You can delete the existing file or select
an unused destination program number.
Until the stick has finished initializing, a message will
appear on the display “Data Key Not Ready”. If no stick is
installed, ERROR message will also display.
3.8.17 Deleting welds
The Delete function is used to remove unwanted programs
from memory.
1. In the Maintenance Menu, select
Delete Welds
and
press
Enter
.
2. Use the control knob to select a weld program.
3. Press
Delete
.
You can also use this feature to delete welds from a memory
stick if it has been installed and initialized. Program on the
stick is numbered 100 and higher.
Only existing weld programs are displayed in the