3.8.14 Maintenance Menu
In the Main Menu screen, press
Menu
. This will open the
Maintenance Menu screen. Most functions are password-
protected if this option is selected.
Copy Welds (power source internal memory)
You may want copy an existing weld program as a starting
point for creating a new weld program for a different tube
size using the editing feature.
1. In the Maintenance Menu screen, select
Copy
Welds
and press
Enter
.
2. Enter the program numbers for source weld and
destination weld, then press
Copy
.
The Copy function allows you to copy a weld program
within the power source’s internal memory. (For example,
an existing weld number 2 could be copied to weld
number 10, assuming no program number 10 exists.)
The program will not be deleted from weld number 2;
two copies of the program now exist.
When performing a Copy or Transfer to a destination
program of the same number, the new file does not write
over the existing file. You may delete the existing file or
select an unused destination program number.
Weld numbers 1–99 are files stored in the internal memory
of the power source.
3.8.15 Options Menu
Any changes made on this screen become active
immediately but are lost when the power is switched off. To
maintain changes, press Save after all changes are made on
the screen.
Setting the weld counter
At completion of each weld, the system stores the actual
parameters run and related weld ID number, operator
name, and time and date to print out if necessary. The
weld number sequentially increases by one digit per weld.
You can set/reset the weld counter at any specific number
using the control knob.