
58
A7 MIG Welder
© Kemppi Oy 2020
2002
INTEGRA
TION GUIDE
6.3.6 Touch sensor timing
Startup timing
Touch sensor
RI
TouchSensorOn
Voltage OK
Power off
A
Startup phase
B
Symbol
Description
Min
Typical
Max
Units
A
Startup response time
3
ms
B
Power-on cycle time (voltage setup
time)
150
ms
Touch tool change timing
Previous tool
RI
Relay
TouchSensorToolSel
Ready
B
New tool
Ready
Touch sensor
Symbol
Description
Min
Typical
Max
Units
A
Control response time
3
ms
B
Relay action time
5
ms
Touch response timing
B
Short circuit (touch)
Fast status output
TouchSensed
Symbol
Description
Min
Typical
Max
Units
A
Fast status (hardware output) reaction
time
150
µs
B
Touch signal function reaction time
10
ms
Touch sensor off timing
Touch sensor
RI
TouchSensorOn
Power off
Power on
A
Voltage drop
B
Symbol
Description
Min
Typical
Max
Units
A
Control response time
3
ms
B
Power-off cycle time (voltage drop time)
25
30
ms