background image

 

 

 

Manual KHS Mini System Control MASTER

 

 

42 

 

11.  Accessories  

Tab. 11.1 Optionally available accessories 

 

Optionally available accessories 

FIGURE 

KHS Isolating valve with servo drive 230 V 

686 04 

KHS Isolating valve-plus with spring-reset servo drive (230 V) 

686 05 

KHS drain with overflow monitor 

688 00 

KHS temperature sensor fitting PT 1000 

628 0G / 629 0G 

KHS flow measurement valve 

638 4G / 138 4G 

Leakage water sensor 

620 00 001 

 

 

12.  Wiring instructions for components with electrical connection 

Tab. 12.1 Wiring instructions for components with electrical connection 
 

Designation 

  

For KEMPER 

order no. 

Cable cross-

section 

mm² 

Max. cable 

length 

Cable type* 

KHS Isolating valve-plus with spring-
reset servo drive (230 V) 

68605015…032 
69605015 

3 x 1.5²  

9500 

NYM-J 3 x 1.5mm² 

KHS Isolating valve with servo drive 
(230 V) 

68604015…032 
69604015 

4 x 1.5²  

9500 

NYM-J 4 x 1.5mm² 

KHS drain with overflow monitor 

68800020...032 

2 x 0.25²  

150 

J-Y(ST)Y 1x2x0.6mm² 

or NYM-J 3x1.5mm² 

Kemper Control-plus 
Flow measurement valve Vortex 
principle  

6384G015…025 
1384G015…050 

7 x 0.34² **                             

300 

J-Y(ST)Y 4x2x0.6mm² 

KHS temperature sensor fitting PT 
1000   

6280G015...050                 
6290G015...050  

4 x 2 x 0.6 

10,000 

J-Y(ST)Y 4x2x0.6mm² 

CAN bus cable'*** 
The application is based on the ISO 
11898 international standard.  

68602005 
68602006 

1 x 2 x 0.25² ... 0.34² 
1 x 2 x 0.34² ... 0.5² 
1 x 2 x 0.50² ... 0.6² 
1 x 2 x 0.75² ... 0.8²

 

0 m … 40 m 

40 m … 300 m 

300 m … 600 m 

500 m … 1000 m

 

CAN bus cable 

Leakage water sensor 

6200000100 

2x0.75² 

0-50 

50-500 

Standard cable 

UL-LIYCY 

 

 

 

 

*     Possible cable type for fixed routing 
**   Shielded cable supply lin

 

 

 

 

 

 

Version: 21/11/2013 

*** (To be provided by construction site)

 

 
 

Summary of Contents for 686 02 005

Page 1: ...Installation and operating instructions KEMPER KHS Mini System Control KEMPER KHS Mini System Control MASTER Figure 686 02 005 KHS Mini System Control SLAVE Figure 686 02 006...

Page 2: ...nting 7 6 2 Electrical installation KHS Mini System Control 8 6 2 1Terminal description MASTER and SLAVE 8 6 2 2Detailed illustration of the terminals for cable entry 9 6 2 2 1Power supply connection...

Page 3: ...urnal 33 8 1 4 6 Switching programs 34 8 1 4 7 Valve manual mode 35 8 1 4 8 Error handling 36 8 1 5 Using the USB interface 37 8 2 Configuration PC software 38 9 DESCRIPTION OF MALFUNCTIONS AND MALFUN...

Page 4: ...ntrol If you cannot find the information and instructions you need in these operating instructions ask the manufacturer Gebr Kemper please refer to last page for the address Keep the mounting and oper...

Page 5: ...r exchange Temperature controlled water exchange Volume controlled water exchange 2 2 KHS MASTER SLAVE technology The MASTER SLAVE technology can be used to trigger flushing measures for maintaining t...

Page 6: ...the manufacturer Original spare parts and manufacturer authorised accessories serve the purpose of safety The use of any other parts may annul the liability for any resultant consequences Attention U...

Page 7: ...lts disengageable Alarm acknowledgement on MASTER System is expandable 1 MASTER with max 62 SLAVEs via CAN bus Bus system connection per direction CAN installation cable max 1000m total length overall...

Page 8: ...s and one directly connected KHS water exchange group That means up to 63 KHS water exchange groups can be connected and operated The accumulated total length of one CAN bus connection can amount to a...

Page 9: ...stalled only in the last control component SLAVE of a CAN bus cable line The MASTER control does not require a terminal resistance Variant 2 Ill 5 3 Illustration of a CAN bus line with terminal resist...

Page 10: ...with an a c mains filter Inductive loads must be equipped with safeguards to reduce overvoltages varistors RC filter Attention When using the controller together with other devices in one system chec...

Page 11: ...D 1 ______________________________________ 11 CAN Bus HIGH 2 _____________________________________ 12 CAN Bus LOW 2______________________________________ 13 CAN Bus GND 2 _____________________________...

Page 12: ...preceding warning notices 6 2 2 1 Power supply connection Power supply 230 V 15 AC 50 60Hz Connection Terminals L N PE Line fuse max 16A BN brown L BU blue N GR green PE Ill 6 3 Schematic representat...

Page 13: ...ive 6 2 2 4 CAN bus connection Attention Follow the notices and instructions in Chapter 5 The twisted pair of the CAN bus cable should be separated and the shielding removed only as far as necessary t...

Page 14: ...m of connection of external switch Note Through the trigger on Terminal 6 you have a facility to switch the KHS Mini System Control program with external switching processes through a 230V input The p...

Page 15: ...ement is needed or a Pt 1000 connected insulate and protect the strands from contact with the board GY grey green yellow 19 W white 20 Ill 6 10 Schematic diagram of connection of KHS CONTROL PLUS volu...

Page 16: ...white 20 W white 21 Ill 6 13 Schematic diagram of connection of KHS Temperature Measurement Valve Pt 1000 6 2 2 8 Connection of KHS drain with overflow monitor Figure 688 00 Note In the as delivered...

Page 17: ...50m to 500m as shielded cable 2x 0 75 mm e g UL LIYCY W white 22 BN brown 23 Ill 6 15 Exemplary diagram of the water sensor connection 6 2 2 10 Connection of floating alarm relay Monitoring example E...

Page 18: ...electricians to assemble and install electrical equipment Danger of fatal electric shock ATTENTION Note To simplify the control system and to guarantee flawless installation fill in the overview of t...

Page 19: ...tions of the sample project in the following chapters Ill 8 1 and 8 2 After all units as described in Chapter 6 have been mounted and electrically connected the actual configuration of the individual...

Page 20: ...menu item jumps back to the first menu item Likewise pressing the button changes from the first to the last menu item Note If no entry is made for three minutes the control reverts from the setting m...

Page 21: ...tionally press the or button to select another active controller It is indicated again through a flashing frame If you now press the OK button the detailed overview of another controller appears Legen...

Page 22: ...ER and two KHS Mini System Controls SLAVE Legend symbols Water exchange activated Valve symbol is framed Time control Time symbol flashes Volume control Volume symbol flashes Temperature control Tempe...

Page 23: ...menu there are the sub menus System settings Can bus setup Device settings Operating modes Journal Switch program Valve manual mode Network setup see Ill 8 8 and Ill 8 9 Ill 8 8 Main menu top Ill 8 9...

Page 24: ...hange the selected digit Press the OK button to confirm and to select the next digit Pressing OK again stores the set time and the system control submenu opens again Date In the system control submenu...

Page 25: ...gain Display contrast Use the Display contrast menu item to set the display contrast To do that select the Display contrast menu item in the system control submenu with OK Press the and buttons to cha...

Page 26: ...m control submenu opens again Default settings To reset the control to the default settings select the menu item Default setting in the system control submenu with OK A query then opens If it is ackno...

Page 27: ...system To add a KHS Mini System control the desired position has to be specified in the CAN BUS Setup submenu with OK Subsequently the serial numbers of all connected KHS Mini System Controls SLAVES a...

Page 28: ...the desired control Then select the desired linking option controller type valve type sensor type alarm relay display operating cycles with OK After that a selection opens in which the related compon...

Page 29: ...e project being used the KHS Mini System Control MASTER should trigger a C valve in the form of a VAV maximum flow isolating ball valve with spring reset servo drive Furthermore a KHS CONTROL PLUS flo...

Page 30: ...on of a safety device Device selection Control type Valve Ill 8 28 Configuration of safeguard Configuration of SLAVE 1 2 C valve The KHS Mini System Control SLAVE 1 2 in this sample project should tri...

Page 31: ...hoose which programs will be selected Press OK again to open the specific setting facilities depending on the program They are explained in detail based on the sample project Device selection Choose l...

Page 32: ...nfiguration of the Temperature flushing operating mode Temperature flushing Ill 8 32 Configuration of temperature flushing Time flushing The KHS Mini System Control MASTER in this sample project is co...

Page 33: ...ed the safety valve is open the whole day and only reacts to a signal from the water sensor Ill 8 34 Configuration of a safeguard Configuration of a SLAVE 1 2 volume flushing The KHS Mini System Contr...

Page 34: ...stored with one KHS Mini System Control Routine time If there is no temperature flushing within 7 days the water exchange is guaranteed through the Routine time operating mode For the Routine time op...

Page 35: ...m flushing time of the water exchange can be stored in the Routine volume operating mode Illustration 8 38 shows the individual steps for configuration Ill 8 38 Configuration of routine volume Note Af...

Page 36: ...KHS Mini System Control for an example see Ill 8 39 Up to 50 000 journal entries can be saved Based on the documentation about the locality duration of the water exchange and the temperatures recordi...

Page 37: ...the Switch program submenu The External input or External switch can be assigned to a program switch in this submenu The functions are described in Illustration 8 40 Note The two mentioned flushing pr...

Page 38: ...al mode operating mode Furthermore the valves can be individually triggered during maintenance The functions are simulated in Illustration 8 41 Maintenance A function test is recommended after configu...

Page 39: ...t kind of impact the malfunction could have on the system The control goes into alarm latching and has to be acknowledged after the malfunction has been repaired Ill 8 43 Error display Ill 8 44 Acknow...

Page 40: ...CFG file and new software updates UPD file can be written to the KHS Mini System Control MASTER The functions are simulated in Illustration 8 45 Note The USB menu is not visible in normal mode The men...

Page 41: ...PC software Note The configuration of the PC software is explained in a separate operating instruction You find this manual on our website www kemper olpe de or with the PC software itself To use the...

Page 42: ...rol Volume flushing switched off during runtime Set volume not reached Check the installation setup and the maximum flushing time Error message Volume operating mode is blocked in the defective contro...

Page 43: ...Affected SLAVEs do not function Table 9 2 Description of warnings notices Description of warnings notices Status LED on Slave Error Potential cause Measures Impact Warnings Flashes red 1 sec Operatin...

Page 44: ...ER 41 10 Dimensions attachment dimensions Hole clearances MASTER Ill 10 1 Dimensions and hole clearances for attachment holes on the MASTER Hole clearances SLAVE Ill 10 2 Dimensions and hole clearance...

Page 45: ...drive 230 V 68605015 032 69605015 3 x 1 5 9500 NYM J 3 x 1 5mm KHS Isolating valve with servo drive 230 V 68604015 032 69604015 4 x 1 5 9500 NYM J 4 x 1 5mm KHS drain with overflow monitor 68800020 03...

Page 46: ...ine or one individual distribution line without dependence on the other water exchanging valves KHS Isolating valve with servo drive Figure 686 04 230 V AC Figure 696 04 230 V AC Discharge water limit...

Page 47: ...Manual KHS Mini System Control MASTER 44 13 2 Overview for the system commissioning of the KHS Mini System Control...

Page 48: ...Manual KHS Mini System Control MASTER 45...

Page 49: ...Manual KHS Mini System Control MASTER 46 NOTES...

Page 50: ...acturer Gebr Kemper GmbH Co KG Metallwerke Harkortstr 5 D 57462 Olpe Tel 49 2761 891 0 Fax 49 2761 891 175 info kemper olpe de www kemper olpe de K410068602005 00 09 14 We reserve the right to make te...

Reviews: