13. Alarm
This function features to inform with an alarm sound when the
measured data exceeds the preset WBGT reading. The alarm
function is effective only for WBGT reading.
C
onfigurable range of alarm: 15.0°C to 40.0°C
(Default: 28.0°C)
The setting needs to be set to OFF in the screen of changing
settings to stop the alarm sound. The alarm sound will stop when
the measurement data is below the preset threshold.
Select the alarm icon from the screen of changing settings.
Alarm threshold
Notice
Keeping the alarm sounding results in shortening the battery
life.
Warning
Regularly check the reading on the display when using this
product in the environment where the alarm sound is hard
to hear in such an occasion that there is a sound source
around or this product is located far away from the operator.
Select ON/OFF
When ‘ON’ is selected, go to
Alarm threshold setting
S
et alarm threshold and press “OK” button to complete the settings.