background image

 

 

  

 

www.

kem

-kueppers.com 

 

info

@kem-kueppers.com 

 
 
 
 
 
 
 
 
 

Instruction Manual 

 

 

SV Sensor Adaptor 

To connect KEM Flow Meters with an  

EX II 2G D Electronic Device 

 

Summary of Contents for SV Series

Page 1: ...www kem kueppers com info kem kueppers com Instruction Manual SV Sensor Adaptor To connect KEM Flow Meters with an EX II 2G D Electronic Device ...

Page 2: ...2 Version Version SV_M_EN_170515_E003 Manual Version SV_M_EN_170515_E003 ...

Page 3: ...4 Symbols marked on equipment 5 1 3 Ex protection 6 1 3 1 Ex Supply Data 6 1 3 2 Ambient Temperature 6 1 3 3 Markings 6 1 4 Ordering code 7 2 ASSEMBLY 8 2 1 Constituent parts 8 2 2 Installing instructions 8 2 3 Dimensional drawing 9 2 4 Sensor types 10 2 4 1 Electrical Parameter of the Inductive Coil 10 2 4 2 Electrical Parameters of the carrier frequency coil 10 2 4 3 Grounding 10 2 5 List of ill...

Page 4: ...function of the product can reasonably be expected to result in a personal injury Customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify the manufacturer and supplier for any damages resulting from such improper use or sale Electrostatic discharge does inflict irreparable damage to electronics Before installing or opening the uni...

Page 5: ... with the safety precautions taken then inform the owner or principal responsible e The local labor and safety laws and regulations must be adhered to f The manufacturer accepts no responsibility whatsoever if the following safety rules precautions instructions and the procedures as described in this manual are not followed h Modifications or repair of the flamepath is not allowed 1 2 3 Warnings i...

Page 6: ...owered Power Pi 0 11 W 1 3 2 Ambient Temperature 40 F to 185 F 40 C to 85 C 1 3 3 Markings KEM Küppers Elektromechanik GmbH Liebigstr 5 D 85757 Karlsfeld Typcode SV Labelling ATEX RL 0123 Ex II 2G ATEX IECEx Ex db IIC Gb Amb Temp 40 F to 185 F 40 C bis 85 C Certifications Sira 16ATEX1261U IECEx SIR 16 0089U Warnings Do not open when an explosive atmosphere is present Do not open when energized See...

Page 7: ...7 General Information Version SV_M_EN_170515_E003 1 4 Ordering code ...

Page 8: ...or gets assembled to correct sensor connections which are stated in the type code of the sensor adaptor Screw in the adaptor gently by hand until you feel that it touches the ground Then turn it back for a quarter turn Secure the position with the counternut and make sure that the wedge lock washer is in between This washer is necessary to make sure that the counternut can not get loose while the ...

Page 9: ...9 Assembly Version SV_M_EN_170515_E003 2 3 Dimensional drawing Fig 2 Dimensional drawing Sensor type Length T K I K 1 57 in 40 mm T L I L 3 15 in 80 mm T R 1 81 in 46 mm T S 3 39 in 86 mm ...

Page 10: ...n 70 Ω Inductance Max 30 mH Coil supply Current 200 µA Voltage 5 V for Operational amplifier 2 4 2 Electrical Parameters of the carrier frequency coil Wire diameter 60 µm Resistance Min 16 Ω Inductance Max 2 mH Coil supply Current Colpittz Oscillator 1 mA Voltage 5 V 2 4 3 Grounding A M5 thread is implemented for grounding Fig 3 Grounding ...

Page 11: ...11 Assembly Version SV_M_EN_170515_E003 2 5 List of illustrations Fig 1 Assembly with part numbering 8 Fig 2 Dimensional drawing 9 Fig 3 Grounding 10 ...

Page 12: ...49 9941 9423 23 production kem kueppers com KEM Sales Liebigstraße 5 85757 Karlsfeld Deutschland T 49 8131 59391 100 F 49 8131 92604 sales kem kueppers com KEM Service Repairs Wettzeller Straße 22 93444 Bad Kötzting Deutschland T 49 9941 9423 37 F 49 9941 9423 24 service kem kueppers com More distributors and partners can be found at www kem kueppers com Original KEM document SV_M_EN_170515_E003 C...