background image

Window Wall (Manual) Room Air Conditioner

User Manual

KWH15CME

Refrigerant R32

Congratulations Contents

Congratulations and thank you for choosing our Manual Window Wall room air conditioner. We are sure you will find
your new air conditioner a pleasure to use. Before you use the air conditioner, we recommend that you read
through the entire user manual, which provides the description of the air conditioner and its functions.
To avoid the risks that are always present when you use an electrical appliance, it is important that the air
conditioner
is installed correctly and that you read the safety instructions carefully to avoid misuse and hazards.
We recommend that you keep this instruction booklet for future reference and pass it on to any future owners.
After unpacking the air conditioner please check it is not damaged. If in doubt, do not use the air conditioner but
contact your local Electrolux Customer Care Centre.

environmental tip

Information on disposal for users
• Most of the packing materials are recyclable. Please dispose of those materials through your local recycling depot

or by placing them in appropriate collection containers.

• If you wish to discard this air conditioner, please contact your local authorities and ask for the correct method

of disposal.

• This product contains refrigerant which must be reclaimed by a licensed refrigeration mechanic before the

product can be disposed of.

Safety precautions 3

Prior to operation 4

Unit parts identification 5

Air conditioner features 5

Care and cleaning 7

Specifications 8

Installation 8

Troubleshooting 10

warning

This unit uses refrigerant R32 and must be disposed of by a licensed refrigeration mechanic with knowledge of
appropriate gas reclamation methods.

caution

• The air conditioner is not intended for use by young children or infirm persons without supervision.
• Young children should be supervised to ensure that they do not play with the air conditioner.
• Contact an authorised installer for installation of this unit.
• Contact an authorised service technician for repair or maintenance of this unit.
• If the power cord is to be replaced, replacement work must be performed by authorised personnel only.
• Installation work must be performed in accordance with the national wiring Standards by authorised personnel

only.

Safety precautions

caution

• Contact an authorised service technician for repair or maintenance of this unit.

Summary of Contents for KWH15CME

Page 1: ...y placing them in appropriate collection containers If you wish to discard this air conditioner please contact your local authorities and ask for the correct method of disposal This product contains refrigerant which must be reclaimed by a licensed refrigeration mechanic before the product can be disposed of Safety precautions 3 Prior to operation 4 Unit parts identification 5 Air conditioner featu...

Page 2: ...tion concerning your personal safety caution This symbol indicates information on how to avoid damaging the appliance tips and information This symbol indicates tips and information about use of the appliance environmental tip This symbol indicates tips and information about economical and ecological use of the appliance warning Do not use means to accelerate the defrosting process or to clean oth...

Page 3: ...explosion fire and burns Do not disassemble or modify unit It may cause failure and electric shock This symbol indicates never to do this This symbol indicates always do this Safety precautions When the air filter is to be removed do not touch the metal parts of the unit It may cause an injury Do not clean the air conditioner with water Water may enter the unit and degrade the insulation It may caus...

Page 4: ... and could make you sick caution Prior to Operation Preparing for operation 1 Contact an installation specialist for installation 2 Plug in the power plug properly 3 Do not use a damaged or non standard power cord 4 Do not share the same outlet with other appliances 5 Do not use an extension cord 6 Do not start stop operation by plugging unplugging the power cord Usage 1 Exposure to direct airflow ...

Page 5: ...ling effect and airflow LOW COOL has minimum cooling effect and airflow OFF will completely shut off the unit Electrical work Under normal circumstances there is no reason to modify the electrical connection In case it is required a qualified service technician should perform this task 1 Power cord conductors are distinguished according to colour as follows see Fig 1 2 For your safety and protection thi...

Page 6: ...hen the AIR SWING switch is turned to ON position the vertical louvres automatically oscillate right and left sweeping the cold air around to obtain comfortable cooling The vertical louvres may be stopped at any position when the AIR SWING switch is turned OFF AUTO SWING OFF ON On somemodels For the units without AIR SWING feature manually To adjust horizontal air flow direction move the lever gent...

Page 7: ... detergent Rinse thoroughly and wipe dry Never use harsh cleaners wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner NOTE Never use water over 50oC alcohol gasoline acid solvent or brush to clean the front panel as this will damage th...

Page 8: ...ect a suitable sized drain hose not supplied to the drain outlet located on the underside of the drain pan screw rubber Step 2 Removing the front panel 1 Remove the screw from the frame see Fig 3 2 Grasp the left corner in the frame s underside then loosen the frame see Fig 4 Step 3 Installation 1 Remove the screw fix the chassis fixing board and cabinet 2 Grasp the handle on the chassis and careful...

Page 9: ...o remove Stored heat from walls ceiling floor and furniture Air conditioner turns on and off rapidly Dirty air filter air restricted Clean air filter Outside temperature extremely hot Set to high cool to bring air past cooling coils more frequently Noise when unit is cooling Air movement sound This is normal If too loud turn selector to lower FAN setting Sound of fan hitting water moisture removal sys...

Page 10: ... customer that the Appliance was installed in accordance with Electrolux installation guidelines as set out in the installation manual ii the Appliance rating is correct for the size and thermal characteristics of the room iii the Appliance has been regularly maintained in accordance with Electrolux guidelines as set out in the user manual iv the Appliance is designed for providing human comfort a...

Page 11: ... benefits to you given by this warranty are in addition to your other rights and remedies under a law in relation to the Appliances or services to which the warranty relates 11 At all times during the Warranty Period Electrolux shall at its discretion determine whether repair replacement or refund will apply if an Appliance has a valid warranty claim applicable to it 12 To enquire about claiming un...