background image

2010

20

66129904148

Summary of Contents for Cooling Only

Page 1: ...2010 20 66129904148 ...

Page 2: ... maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or infirmed persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replaced replacement work shall be performed by authorised personnel only Installation work must be ...

Page 3: ...use fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of unit or electric shock It may cause fire and electric shock It may cause fire and electric shock It may cause electric shock or fire If the power cord is damaged it must be replaced by the manufac turer or an authorised service centre or a si...

Page 4: ...eterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service technician 3 It may cause failure of appliance or accid...

Page 5: ...hen used together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purposes e g Preserving precision devices food pets plants and art objects Usage in such a manner could harm such property 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air ...

Page 6: ...CLOCK SWING TIMERON TIMEROFF ENERGY SAVER SLEEP LIGHT FAN ON OFF MODE ...

Page 7: ...nt This will allow internal air circulation OPEN the vent to discharge stale air The electronic control keypad will look like one of the following To open the vent set the lever to the right position To close it set the lever in the left position OPEN 6 VENT CLOSE 9 000BTU h Models 9 000BTU h Models SWIN FILTER FAN MOD POWER LOW AUTO COOL DRY FAN TIMER SWIN FILTER FAN MOD POWER LOW AUTO COOL DRY F...

Page 8: ... tional within 0 10 hours and 1 hour increments within 10 24 hours within 0 10 hours and 1 hour decrements within 10 24 hours TIMER Press the TIMER keypad to activate the auto start auto stop timer function Auto start stop programs can be set from 1 2 24 hours Each depression of the TIMER keypad will increase the selected time in 1 2 hour increments within 0 10 hours and 1 hour increments within 1...

Page 9: ...ling temperature set point is 25 o C motor to stop Note This Function can only be activated by remote control Please refer to remote operating instruction for more detail information heating temperature set point FILTER This feature is a reminder to clean the Air Filter See Air Filter for more efficient operation The light will illuminate after 250 hours of operation To reset after cleaning the fi...

Page 10: ...LIGHT Turn the unit LED light on or off only ENERGY SAVER Activate the ENERGY SAVER mode CLOCK Press this button to set clock CLOCK SWING TIMERON TIMEROFF ENERGY SAVER SLEEP LIGHT FAN ON OFF MODE ...

Page 11: ...on the display will blink and during 5 seconds blinking the value can be adjusted by pressing or button every press of this button 1 2 hour will be increased or decreased but continuously press the or button 2 seconds later the value will be changed quickly 1 2 hour will be increased in every 1 4 second automatically by the remote controller During blinking press the TIMER ON button to confirm the...

Page 12: ...ress MODE and buttons simultaneously to switch ć and INTRODUCTION FOR SPECIAL FUNCTION ABOUT LOCK Press this button at unit On the light on the main unit will be turned on or off Light On is defaulted when power on LIGHT Press this button the clock can be set up icon blinks Within 5 seconds the value can be adjusted by pressing or button if continuously press this button for 2 seconds above in eve...

Page 13: ...12 ...

Page 14: ...13 ...

Page 15: ...ndensate to run to the about 10mm or 1 4 bubble with level 5 Install the unit with its bottom portion 75 150cm above the floor level 6 The power cord must be connected to an independent circuit The yellow green wire must be earthed 7 In some light construction walls there may be a requirement for the addition of a foam or rubber strip between the air conditioner housing and the wall cavity The add...

Page 16: ...SURE LOUVRES ARE ENTIRELY OUTSIDE THE WALL Hole in the wall Unit housing Foam strip Step 1 Remove the air conditioner from it s packaging remove fixing screws and slide the air conditioner out of it s housing Refer to Installation Steps Step 2 Prepare the hole in the wall so that the bottom of the housing is well supported the top has minimum clearance and the air inlet louvres have clearance as s...

Page 17: ...en remove the chassis fixing brackets 2 Grasp the handle on the chassis and carefully slide the air conditioner out of the cabinet See Fig 8 3 Remove shipping pad if fitted from around compressor before operation Failure to do so may damage the Compressor And make sure the discharge points to the drain pan are aligned before the chassis is pushed into the cabinet See Fig 9 4 Push the unit chass is...

Page 18: ...fuse is blown circuit breaker is tripped Check the house fuse circuit breaker box and replace the fuse or reset the breaker Power failure If power failure occurs switch off and disconnect unplug the power cord When power is restored reconnect plug in the power cord switch on the power and wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload Airflow is restri...

Page 19: ...ccident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect power supply v incomplete or improper installation vi incorrect improper or inappropriate operation vii insect or vermin infestation b The Appliance is modified without authority from Electrolux in writing c The Appliance s serial number or warr...

Page 20: ...66129904148 ...