2,4 

¤¤      ¤¤¤¤ 

Throttle error at 
power up 

1.  The throttle signal is higher than configured 

dead zone at power-on   

2.  The fault will disappear if restarts or releases 

throttle. 

3.  Configure throttle type as "Hall Active" throttle if 

you use that type. 

3,1 

¤¤¤    ¤ 

Frequent reset 
 

1.  The controller will stop driving after detecting 

too many resets. 

2.  Mostly because of B- or return wiring. Use the       

heavier and cleaner return wires. For dual                   

      controllers, bond B- of both controllers together               

      with heavy cable or copper strip. 

3.  Could be over current protection. May set max     

      current lower. 

4.    Restarting will clear the error. 

5.    Please contact Kelly if it happens repeatedly. 

3,2 

¤¤¤    ¤¤ 

Internal reset

 

Reset caused by over current, high battery voltage 

or low supply voltage. It is normal if occurs 

occasionally. 

3,3 

¤¤¤    ¤¤¤ 

Throttle short or 
open circuit when 
using 1-4v hall 
sensor throttle 

1. Check whether the throttle is short or open 

circuit. 

2.   When the throttle is normal, restart will clear the 

      error. 

3,4 

¤¤¤    ¤¤¤¤ 

Throttle isn’t zero 
when try to 
change direction 

The controller won’t change drive direction if 
throttle isn’t zero. Also it won’t change direction at 
high speed. The controller will wait throttle and 

speed close to zero before changing direction. 

4,1 

¤¤¤¤    ¤ 

Over voltage at 
startup or 
regeneration 

The controller won’t drive motor if detects 
overvoltage at power up. It will cut back regen 

current or stop regen at overvoltage. You may set 

max voltage threshold with GUI.   

4, 2 

¤¤¤¤    ¤¤ 

Hall sensor signal 
error 

1. Most likely caused by incorrect hall wiring (to 

wrong pin or loose wire).   

2. Intermittent or damaged hall sensor.   

3. Double check hall angle setting, 60 degree or 

120 degree. 

4, 3 

¤¤¤¤    ¤¤¤ 

Motor over 
temperature 

1. The motor temperature is higher than configured 

max temperature. Controller will shut down and 

wait for motor temperature dropping. 

2. Change the temperature setting with 

configuration program. 

4, 4 

¤¤¤¤     

¤¤¤¤ 

Motor locked rotor 

When in locked rotor condition, the max output 

phase current of the motor will be limited to 90% of 

previous current. Once the locked rotor disappear, 

Summary of Contents for KEB Series

Page 1: ...s Manual V 3 3 Kelly KEB Brushless Motor Controller User s Manual Devices Supported KEB48220 KEB48221 KEB48300 KEB48301 KEB48400 KEB48401 KEB48600 KEB48601 KEB72330 KEB72331 KEB72450 KEB72451 KEB7260...

Page 2: ...r 2 Main Features and Specifications 3 2 1 General functions 3 2 2 Features 4 2 3 Specifications 4 2 4 Models 5 Chapter 3 Wiring and Installation 6 3 1 Mounting the Controller 6 3 2 Connections 7 3 3...

Page 3: ...ly s programmable KEB motor controllers provide efficient smooth and quiet controls for electric bicycles electric motorcycles scooters etc It outputs high taking off current and strictly limit batter...

Page 4: ...9 Provide power supply 5V for hall sensors and other sensors 10 3 switch inputs Default to throttle switch brake switch and reversing switch Closing to ground is to activate 11 3 analog inputs 0 5V D...

Page 5: ...ironment Rugged high current terminals and rugged aviation connectors for small signal Thermal protection current cut back warning and shutdown on high temperature Configurable 60 degree or 120 degree...

Page 6: ...Brake and Throttle Input 0 5 Volts Producing 0 5V signal with 3 wire pot Full Power Operating Temperature Range 0 to 50 controller case temperature Operating Temperature Range 30 to 90 100 shutdown c...

Page 7: ...ntaminants To ensure full rated output power the controller should be fastened to a clean flat metal surface with four screws Applying silicon gel or other thermal conductive material to contact surfa...

Page 8: ...wn as Figure 2 Figure 2 Front panel of KEB motor controller B battery positive B battery negative A Output U 1 A phase B Output V 2 B phase C Output W 3 C phase Figure 3 The connecting diagram of J2 J...

Page 9: ...TN pins are internally connected RTN is internally connected to B 2 Switch to ground is active Open switch is inactive Caution Make sure all connections are correct before applying power Otherwise it...

Page 10: ...lly Ebike Brushless DC Motor Controller User s Manual V 3 3 Page 9 3 2 2 Standard Wiring of KEB Motor Controller Figure 4 KEB controller standard wiring Battery voltage can be used for controller supp...

Page 11: ...eckout Make sure both the PWR switch and the brake are off Use well insulated tools Make sure the wire is connected correctly Turn the PWR switch on The LED should blink then keep on when the controll...

Page 12: ...d be wiped down with a moist rag Be sure it is dry before reconnecting the battery Make sure the connections to the bus bars are tight Use two wrenches for this task in order to avoid stressing the bu...

Page 13: ...ler will attempt to clear the fault code automatically after 5 second if battery voltage returns to normal 2 Check the battery voltage 3 Charge battery if necessary 1 4 Over temperature warning 1 The...

Page 14: ...short or open circuit 2 When the throttle is normal restart will clear the error 3 4 Throttle isn t zero when try to change direction The controller won t change drive direction if throttle isn t zero...

Page 15: ...D flashes once at power on then keeps off for normal operation 1 2 means it flashed once then flashes twice after 1 second The time between two flashes is 0 5 second The pause time between one error c...

Reviews: