Kelly KBS Brushless Motor Controller User’s Manual
V 4.1
3
Chapter 2 Features and Specifications
2.1 General functions
(1) Extended fault detection and protection. The LED flashing pattern indicates the fault
sources.
(2) Monitoring battery voltage. It will stop driving if the battery voltage is too high and it will
progressively cut back motor drive power as battery voltage drops until it cuts out
altogether at the preset “Low Battery Voltage” setting.
(3) Built-in current loop and over current protection.
(4) Configurable motor temperature protection range.
(5) Current cutback at low temperature and high temperature to protect battery and controller.
The current begins to ramp down at 90
℃
case temperature, shutting down at 100
℃
.
(6) The controller keeps monitoring battery recharging voltage during regenerative braking,
progressively cutting back current as battery voltage rises then cutting off regen altogether
when voltage goes too high.
(7) Maximum reverse speed is configurable to half of the maximum forward speed.
(8) An RS232 port allows for configuration, programming and software upgrades using the
free Windows GUI with your PC.
(9) Provision of a +5 volt output to supply various kinds of sensors, including Hall effect type.
(10) 3 switch inputs which are activated by connection to Ground. Default to throttle switch,
brake switch and reversing switch.
(11) 3 analog 0-5V inputs that default to throttle input, brake input and motor temperature input
(12) Pulsed reverse alarm output.
(13) Main contactor driver. Cutting off the power if any fault is detected.
(14) Current meter to display both drive and regen current. Save shunt!
(15) Configurable boost switch. Enables the maximum output power achievable if the switch is
turned on.
(16) Configurable economy switch. Limits the maximum current to half if the switch is turned on.
(17) Maximum reverse power is configurable to half power.
(18) Enhanced regen brake function. A novel ABS technique provides powerful and smooth
regen.
(19) Configurable 12V brake signal input, in lieu of motor temperature sensor.
(20) Optional joystick throttle. A bi-symmetrical 0-5V signal for both forward and reversing.
(21) Configurable motor over-temperature detection and protection with the recommended
thermistor KTY84-130.
(22) 3 hall position sensor inputs. Open collector, pull up provided.
(23) Optional supply voltage 8V-30V.
Caution!
Regeneration has braking effect but does not replace the function of a mechanical
brake. A mechanical brake is required to stop your vehicle. Regen IS NOT a safety feature!
Controller may stop regen, without warning, to protect itself or the battery(it won’t protect you!).