MANUAL
LEO 5
Keller AG für Druckmesstechnik
Page 1: ...MANUAL LEO 5 Keller AG f r Druckmesstechnik...
Page 2: ...xample Setting the peak mode 5 2 2 2 Handling example How to stop the peak mode 5 2 3 Menu structure 6 2 3 1 Main menu 6 2 3 2 Sub menu 7 2 3 3 Sub menu settings 10 2 4 USB connection 12 2 5 Installin...
Page 3: ...uctions 2 1 Touch Display LEO 5 has two keys integrated into the display A key press is initiated by touching the key field SELECT or ENTER and activated by release the key for at least 0 5 second rel...
Page 4: ...2 Manage the device with touch pannels choose different functions press SELECT activate commands or functions press ENTER Remark The display automatically switches back to the main display 10 seconds...
Page 5: ...t will show MENU Press ENTER Press SELECT key 3 times The lower display part will show PEAK and START Press ENTER In the main display the segment PEAK indicates that the peak mode is on 2 2 2 Handling...
Page 6: ...ler druck com 6 2 3 Menu structure 2 3 1 Main menu Main Display Reset Min Max value are set to the actual pressure OFF Turns off the instrument and ends an active record Menu Releases the sub menu fun...
Page 7: ...onfiguration set via the software Rec OFF Ends an active record Peak START PEAK off Normal measuring mode with 2 measurements per second PEAK on Fast measuring mode with 5000 measurements per second R...
Page 8: ...com 8 Zero SET Sets a new pressure zero reference Zero RESET Sets the pressure zero to factory setting UNIT Unit selection CONT Activates or deactivates the automatic turn off function Display Main d...
Page 9: ...com 9 BACKL Backlight setting RESL Choose resolution ACCU Accumulator information and charge status EXIT Each sub menu can be left by pressing ENTER while EXIT is displayed The display will switch bac...
Page 10: ...a MPa PSI kp cm 2 cmH2O mH2O inH2O ftH2O mmHg inHg CONT on Deactivates the automatic turn off function CONT off Activates the automatic turn off function the instrument turns off 15 minutes after the...
Page 11: ...he backlight for 10 seconds after key is pressed set measurement value resolution between 0 to 4 decimal places displays accumulator voltage and visualizes the charge level 3 2 Volt is an empty 4 2 Vo...
Page 12: ...connect the device to USB remove the backside mounted rubber protection to access the USB plug Hint The rubber also acts as over pressure safety valve in case of damages at the pressure sensor when in...
Page 13: ...nect the LEO5 with the PC by a USB cable After the PC has detected this device the following message will appear USB Device not recognized Link to the driver http www keller druck2 ch swupdate DriverM...
Page 14: ...www keller druck com 14 Please follow the introduction shown in the picture to install the driver choose the path where the driver is stored...
Page 15: ...www keller druck com 15 The Computer starts to install the new driver Windows doesn t recognize the driver Please click on Continue Anyway...
Page 16: ...gnized windows The device manager is listing the device as Manometer with assigned comport number This com port number must be select manually in the PC software Remark If the device is connected to U...
Page 17: ...vice Manager and go to the section Bluetooth Perform a right click on the Bluetooth device If the Bluetooth is ready to use the device status shows This device is working properly Otherwise please act...
Page 18: ...www keller druck com 18 picture 1 1 picture 1 2...
Page 19: ...he LEO 5 is found The name from the LEO 5 is Manometer and the serial number If device is not found search again until the device is listed in the window May it takes a few tries to detect the device...
Page 20: ...ulator connected the device via USB to a PC or USB main adaptor Check the charge status with sub menu Accumulator on LEO5 or read charge status with the PC software 3 Disposal This product must not be...
Page 21: ...manometer attention must be paid to the corresponding safety regulations Only mount the digital manometer onto unpressurized systems On pressure ranges 61 bar the pressure connections could show resi...