13.1.4 Smoothing function
When the target object’s temperature is erratic, it makes sense to
smooth these temperature fluctuations in order to stabilize the signal.
The greater the time constant t
98,
(user-definable), the lower the effect of
these fluctuations on the yielded temper
ature reading. The pyrometer’s
response time is proportional to the time constant. Set signal smoothing
via parameter
C001
/
FIL.1.
CellaPort models PT 110/113 which
have a thermopile sensor also fea
ture „automatic averaging“. This facili-
tates a steady measurement, on the one hand, and enables fast re-
sponse times on the other hand when temperatures become erratic. This
function is activated as a default setting.