Summary of Contents for 95001000

Page 1: ......

Page 2: ...the forefront of luxury showering Kelda is injecting magic into the showering experience to transform the everyday bathroom into a place of personal sanctuary and tranquility Kelda s unique BubbleRain...

Page 3: ...connections must be completed before making the electrical connections 5 Water Pressure A 1 5 bar mixed supply is required as a minimum at the valve output If using a low pressure gravity fed system a...

Page 4: ...int Tilting of the BubbleSpa Overhead Shower can be in any direction All dimensions are in mm unless otherwise stated 300 380 27 10 8 118 300 46 78 105 1 2 BSP 10 Max tilt of Ball Joint 300 380 27 10...

Page 5: ...System Diagram BubbleSpa Wall Arm Valve 2 1 3 5 4 No Part Qty 1 Wall Arm Extrusion 1 2 Water Path Connector 1 3 Wall Screws Self Tapping 4 2 x 38mm 4 4 Wall Plugs 4 5 BubbleSpa Overhead Shower 1 5...

Page 6: ...Drawing shows the lengths of the parts as supplied The Inner Pipe can be cut down to an appropriate length if necessary The tilting of the BubbleSpa Overhead Shower can be in any direction All dimens...

Page 7: ...6 4 8 2 3 1 9 5 5 4 7 No Part Qty 1 Ceiling Arm Extrusion 1 2 Ceiling Arm Bracket 1 3 Ceiling Arm Trim 1 4 Wall Screws Self Tapping 4 2 x 38mm 6 5 Wall Plugs 6 6 Compression Nut 1 7 Olive 1 8 Mountin...

Page 8: ...1 x1 Wall Arm Assembly x1 Transformer x1 Water Path Connector x1 Hole Guide cut out from page 32 x4 Wall Screws x4 Wall Plugs BubbleSpa Wall Arm Your BubbleSpa shower includes the following assemblie...

Page 9: ...ng Arm Contents 2 Overhead Shower Installation 3 1 x1 Ceiling Arm Assembly x1 Ceiling Arm Trim w Sleeve x1 Ceiling Arm Bracket x1 Transformer x1 Compression Nut x1 Olive x1 Mounting Plate x6 Screws x6...

Page 10: ...Wall Arm Installation 10...

Page 11: ...end prior to commencing installation Screw the Water Path Connecter to the outlet pipe Ensure that the Water Path Connector is no more than 10mm proud of the wall tiles and is no more than 8mm inside...

Page 12: ...ransformer Then turn on the power supply to the Overhead Shower from the mains Ensure that the Overhead Shower is horizontal If the Wall Arm tilts slightly tilt the Overhead Shower from the Ball Joint...

Page 13: ...bubbles do not form as consistently below 20 C Once you are satisfied with the bubbles remove the protective film from the faceplate and enjoy your BubbleSpa shower 10 Once the power is turned on the...

Page 14: ...Ceiling Arm Installation 14...

Page 15: ...r tube will go through the hole with sufficient length to attach the water supply The inner tube may be cut to length if it is too long 3 Warning Read through to the end prior to commencing installati...

Page 16: ...t 5 7 8 Peel back the double sided tape on the Ceiling Arm Bracket and slide on the Ceiling Arm Trim The Ceiling Arm Trim should stick to the tape Silicone may be added on the back of the Ceiling Arm...

Page 17: ...eed to disconnect the power cable first isolate the mains Then pull back the outer layer of the larger connector then remove the small connector 11 Warning Always check for hidden pipes and cables bef...

Page 18: ...an approved electrician in accordance with Part P U K Building Regulations and to the latest IEEE standards or the appropriate regulations in the country of installation 32A 30mA RCBO 3A Switched Fuse...

Page 19: ...nvironment Working Temp Tcase 35 70 C Max Case Temp Tcase 70 C Working Humidity 20 95 RH non condensing Storage Temp Humidity 40 80 C 10 95 RH Temp Coefficient 0 03 C 0 50 C Vibration 10 500Hz 5G 12mi...

Page 20: ...the BubbleSpa shower Wet Mode is automatically activated when water flows through the Overhead Shower above 6L min The default Bubble Mode is 1 Low see table below The Overhead Shower will return to t...

Page 21: ...his function the LED EdgeLight and the fan will turn on To switch off the fan and EdgeLight simply let go of the Button Use this tool to check the function of the fan and EdgeLight Flashing Lights Thi...

Page 22: ...urfaces External surfaces of the Overhead Shower and Arm Assemblies may be wiped clean with a soft cloth and if necessary a mild cleaning or descaling solution can be used Always remove cleaning agent...

Page 23: ...e remount the Overhead Shower reconnect the power cable and turn on the mains power Turn on the water to test the function of the fan If the fan re enters Fan Failure Mode then The maintenance process...

Page 24: ...underside of the Dust Cap and the surface of the Overhead Shower with a damp cloth Take care not to get any moisture on to the fan Cleaning Dust Filters The Dust Cap can be removed from the BubbleSpa...

Page 25: ...the shower for 1 2 minutes to flush out any cleaning solution and debris Descaling the BubbleSpa Overhead Shower The design of the HydrO2 nozzles makes them easy to clean and descale should limescale...

Page 26: ...ent any debris from entering the Overhead Shower Debris in the water system may clog the filters which may result in a lower water flow rate These filters are located inside the Ball Joint To clean or...

Page 27: ...stic Function to see if the fan is working If not contact Kelda Clean the Dust Filters One a few nozzles aren t making bubbles No laminar flow through nozzle Faulty nozzle is blocked Insufficient wate...

Page 28: ...that they are in good order and the packaging is unopened Note returned spares will be subject to a 15 restocking charge and authorisation must be obtained from Kelda Technology before return For the...

Page 29: ...Trading Estate Chandler s Ford Eastleigh SO53 4DR UK Tel 44 0 2381 290640 Web www keldatechnology com DISPOSAL Do not dispose of with household waste Please recycle where facilities exist Check with y...

Page 30: ...Notes 30...

Page 31: ...Notes 31...

Page 32: ...Cut out for installing the Wall Arm Part Number 24011 32...