Model 2790 SourceMeter® Switch System Reference Manual
15-9
Table 15-5
SENSe command summary
Command
Description
Default
parameter
Ref
SCPI
[SENSe[1]]
:FUNCtion <name> [, <clist>]
Select function: ‘VOLTage[:DC]’,
‘VOLTage :AC’, ‘CURRent[:DC]’,
‘CURRent:AC’, ‘RESistance’,
‘FRESistance’, ‘TEMPerature’,
‘FREQuency’, ‘PERiod’, ‘CONTinuity’.
VOLT:DC
✓
:FUNCtion? [<clist>]
Query function.
✓
:DATA[:LATest]?
Return the last reading.
✓
:DATA:FRESh?
Return the last “fresh” reading.
:HOLD
Path to control Hold feature:
:WINDow <NRf>
Set Hold window in % (0.01 to 20).
1
:WINDow?
Query Hold window.
:COUNt <NRf>
Set Hold count; 2 to 100.
5
:COUNt?
Query Hold count.
:STATe <NRf>
Enable or disable Hold.
OFF
:STATe?
Query state of Hold.
:CAVerage <b> [, <clist>]
Channel average calculation (7702 only):
:DELay <NRf> [, <clist>]
Set delay between the two measurements
in seconds (0 to 99999.999).
1
0.5
:DELay? [<clist>]
Query
delay.
[:STATe] <b> [, <clist>]
Enable or disable channel average.
OFF
[:STATe]? [, <clist>]
Query state of channel average.
:RATio <b> [, <clist>]
Channel ratio calculation (7702 only):
OFF
:DELay <NRf> [, <clist>]
Set delay between the two measurements
in seconds (0 to 99999.999).
1
0.5
:DELay? [<clist>]
Query
delay.
[:STATe] <b> [, <clist>]
Enable or disable channel ratio.
OFF
[:STATe]? [, <clist>]
Query state of channel ratio.
7702 <clist> = (@SCH), where: S = Mainframe slot number (1 or 2) and CH= Switching module channel number.
7751/7752/7753 <clist> (DCV,
Ω
2,
Ω
4) = (@Mn) (see
).
Summary of Contents for 2790
Page 3: ......
Page 7: ......
Page 105: ...2 48 Model 2790 SourceMeter Switch System Reference Manual...
Page 245: ...7 40 Model 2790 SourceMeter Switch System Reference Manual...
Page 265: ...8 20 Model 2790 SourceMeter Switch System Reference Manual...
Page 305: ...10 22 Model 2790 SourceMeter Switch System Reference Manual...
Page 328: ...12 CommonCommands...
Page 336: ...13 SCPISignalOriented MeasurementCommands...
Page 345: ...13 10 Model 2790 SourceMeter Switch System Reference Manual...
Page 355: ...14 10 Model 2790 SourceMeter Switch System Reference Manual...
Page 356: ...15 SCPIReferenceTables...
Page 419: ...16 38 Model 2790 SourceMeter Switch System Reference Manual...
Page 461: ...A 2 Specifications Model 2790 SourceMeter Switch System Reference Manual...
Page 462: ...Model 2790 SourceMeter Switch System Reference Manual Specifications A 3...
Page 463: ...A 4 Specifications Model 2790 SourceMeter Switch System Reference Manual...
Page 464: ...Model 2790 SourceMeter Switch System Reference Manual Specifications A 5...
Page 465: ...A 6 Specifications Model 2790 SourceMeter Switch System Reference Manual...
Page 466: ...Model 2790 SourceMeter Switch System Reference Manual Specifications A 7...
Page 471: ...A 12 Specifications Model 2790 SourceMeter Switch System Reference Manual...
Page 472: ...B StatusandErrorMessages...
Page 479: ...B 8 Model 2790 SourceMeter Switch System Reference Manual...
Page 493: ...C 14 Model 2790 SourceMeter Switch System Reference Manaul...
Page 509: ...E 6 Model 2790 SourceMeter Switch System Reference Manual...
Page 510: ...F IEEE 488BusOverview...
Page 525: ...F 16 Model 2790 SourceMeter Switch System Reference Manual...
Page 526: ...G CalibrationReference...