
If an additional manual is required, order the appropriate manual package. The manual
packages include a manual and any pertinent addenda.
Options and accessories
The following options and accessories are available from Keithley for use with the
Model 2182.
Cables, connectors, and adapters
Models 2107-4 and 2107-30 Input Cable
— Connect the Model 2182 Nanovoltmeter to
DUT using one of these input cables. The input cable is terminated with a LEMO connector (for
connection to the Model 2182) on one end and four copper spade lugs (for connection to DUT)
on the other. The Model 2107-4 (which is a supplied accessory to the Model 2182) is 1.2m (4 ft)
in length and the Model 2107-30 is 9m (30 ft) in length. Also included are four copper alligator
clips that attach to the copper lugs of the cable, and DeoxIt copper cleaning solution.
Model 2182-KIT Low Thermal Connector
— Consists of a low-thermal LEMO connector
and strain relief. Includes all the connector parts required to build a custom input cable for the
Model 2182 Nanovoltmeter.
Model 2187-4 Input Cable
— Low-thermal input cable for the Model 2182/2182A. Termi-
nated with a LEMO connector on one end and four banana plugs on the other. The cable is 4 ft
(1.2m) in length.
Model 2188 Low-Thermal Calibration Shorting Plug
— This input shorting plug is
required to calibrate the Model 2182 Nanovoltmeter.
Models 7007-1 and 7007-2 Shielded GPIB Cables
— Connect the Model 2182 to the GPIB
bus using shielded cables and connectors to reduce electromagnetic interference (EMI). The
Model 7007-1 is 1m long; the Model 7007-2 is 2m long.
Model 7009-5 Shielded RS-232 Cable
— 1.5m (5 ft) RS-232 cable terminated with a male
DB-9 connector on one end and a female DB-9 connector on the other end. It is wired as a
straight through (not null modem) cable.
Models 8501-1 and 8501-2 Trigger Link Cables
— Connect the Model 2182 to other
instruments with Trigger Link connectors (e.g., Model 7001 Switch System). The Model 8501-
1 is 1m long; the Model 8501-2 is 2m long.
Model 8502 Trigger Link Adapter
— Lets you connect any of the six Trigger Link lines of
the Model 2182 to instruments that use the standard BNC trigger connectors.
Model 8503 DIN to BNC Trigger Cable
— Lets you connect Trigger Link lines one
(Voltmeter Complete) and two (External Trigger) of the Model 2182 to instruments that use
BNC trigger connectors. The Model 8503 is 1m long.
Silver solder
2182-325A
— Use this Keithley part number to order a 20-foot length of silver solder. Also
included is an MSDS sheet listing the solder chemical contents.
1-4
Getting Started
Summary of Contents for 2182
Page 1: ...www tek com keithley Model 2182 2182A Nanovoltmeter User s Manual 2182A 900 01 Rev B May 2017...
Page 18: ......
Page 22: ......
Page 23: ...1 Getting Started Getting Started...
Page 41: ...2 VoltageandTemperature Measurements Voltageand Temperature Measurements...
Page 68: ...2 28 Voltage and Temperature Measurements...
Page 69: ...3 Range Digits Rate andFilter Range Digits Rate andFilter...
Page 82: ...3 14 Range Digits Rate and Filter...
Page 83: ...4 Relative mX b and Percent Relative mX b andPercent...
Page 91: ...5 RatioandDelta Ratioand Delta...
Page 117: ...6 Buffer Buffer...
Page 123: ...7 Triggering Triggering...
Page 140: ...7 18 Triggering...
Page 141: ...8 Limits Limits...
Page 149: ...9 SteppingandScanning Steppingand Scanning...
Page 168: ...9 20 Stepping and Scanning...
Page 169: ...10 AnalogOutput Analog Output...
Page 175: ...11 RemoteOperation Remote Operation...
Page 205: ...12 CommonCommands Common Commands...
Page 221: ...13 SCPISignalOriented Measurement Commands SCPISignalOri entedMeasure ment Commands...
Page 225: ...14 SCPIReferenceTables SCPIRefer enceTables...
Page 239: ...15 AdditionalSCPI Commands Additional SCPICom mands...
Page 260: ...15 22 Additional SCPI Commands...
Page 261: ...A Specifications Specifications...
Page 263: ...B Statusand ErrorMessages StatusandError Messages...
Page 268: ...B 6 Status and Error Messages...
Page 269: ...C Measurement Considerations Measurement Consider ations...
Page 278: ...C 10 Measurement Considerations...
Page 279: ...D Model182Emulation Commands Model182 EmulationCom mands...
Page 284: ...D 6 Model 182 Emulation Commands...
Page 285: ...E Example Programs ExamplePro grams...
Page 293: ...F IEEE 488 BusOverview IEEE 488Bus Overview...
Page 307: ...G IEEE 488andSCPI ConformanceInformation IEEE 488and SCPIConform anceInforma tion...
Page 310: ...G 4 IEEE 488 and SCPI Conformance Information...
Page 311: ...H Measurement Queries Measurement Queries...
Page 316: ...H 6 Measurement Queries...
Page 317: ...I Delta PulseDelta and DifferentialConductance Delta Pulse Deltaand Dif ferentialCon ductance...