![Kees van der Westen Slim Jim mirage User Manual Download Page 7](http://html1.mh-extra.com/html/kees-van-der-westen/slim-jim-mirage/slim-jim-mirage_user-manual_3884430007.webp)
USER MANUAL - operation
Slim Jim User manual
page 6
Bastone unit
A Bastone unit includes a brew handle, an
indicator LED, a momentary push button and a
two-position toggle switch.
Shortly pressing the brew handle down will start
the pre-set volume determined by the toggle-
switch. A pre-set volume can be stopped before
the volume is reached by shortly pressing the
brew handle again.
When the group is active, the indicator LED is lit.
The push button is the continuous (
“on/off”)
switch with programming function.
The toggle switch determines which of the two
possible pre-set volumes is active.
Figure 4. Bastone unit.
The push button underneath each brew handle
is the continuous (“on/off”) switch equivalent to button
#5 on a touchpad (see below). A continuous dispense can also be stopped by shortly pressing the
brew handle. The indicator light will flash continuously when the controller is in programming mode.
Touchpad
Note!
The main controller can be re-set by a procedure that makes use of the touchpad in combination with
the main switch. You are advised NOT to perform this procedure at any time as you will probably need
a technician to re-program the controller afterwards.
button
A touchpad has 5 momentary push buttons with internal
indicator LED.
The upper button (
, 2 LEDs) is an on/off group switch
with programming function.
Buttons
-
are used to start a pre-set volume. A
pre-set volume can be stopped before the volume is
reached by shortly pressing any button.
When the group is active, the indicator LED of
corresponding button is lit.
Figure 5. Touchpad.(NB: the appearance of the push buttons has changed in 2021.)
Press the upper button briefly to open the group valve and activate the pump, the LED in the button
will light up. Press it briefly again to de-activate the pump and group valve, the LED will go off.
Press-hold the upper button for approximately 10 seconds to get the controller in programming mode
such that shot-volumes (and hot water timer) can be programmed. The indicator LED of the upper
button will flash. Press shortly again to leave programming mode.
For shot-volume programming with Bastone units or touchpads see page 15.
start/stop
volumes
volume 2
←
→
volume 1
on/off group
(program)
indicator LED