background image

14/10/20

KLP

Low Profile

Evaporator

Air, Electric, & Hot Gas Defrost

Electrical Power: 

115/1/60, 208-230/1/60, 208-230/3/60

Bulletin K30-KLPD-PDI-4  

Part # 1109283

PRODUCT DATA & 

INSTALLATION 

PRODUCT SUPPORT

web:

 www.k-rp.com/klp

email: 

[email protected]

call:

 1-844-893-3222 x520

scan:

2
2

3 - 5

6 - 11

11 - 14
15 - 20

21
22
23
24
25

26 - 29
30 - 31
32 - 33

34
35

BACK

INCLUDES RATINGS FOR

STANDARD ON ALL MODELS

see page 15 for details

New Generation "D"

CONTENTS 

 

 

 

 

          

 

 Page

Nomenclature.............................................................................................................................
Features & Options.....................................................................................................................
Selection Data............................................................................................................................
Electrical Data............................................................................................................................
Wiring Diagrams - Models with standard 

 motors ..................................................

Wiring Diagrams - Models with 

 

..................................................................................... 

Annual Walk-In Energy Factor (AWEF) Ratings..............................................................................
Dimensional Data.......................................................................................................................
Shipping Weights........................................................................................................................
Recommended Expansion Valve Selections..................................................................................
Expansion Valve Selections - Models with 

 

......................................................................

Defrost Kit and Fuse Package Selections / Details ....................................................................... 
Installation Instructions..............................................................................................................
Hot Gas Piping Schematics.........................................................................................................
Project Information.....................................................................................................................
Product Support Resources: Service Parts, Troubleshooting, Warranty, etc....................................
“As Built” Service Parts List.........................................................................................................

Summary of Contents for KLP Series

Page 1: ...ALL MODELS see page 15 for details New Generation D CONTENTS Page Nomenclature Features Options Selection Data Electrical Data Wiring Diagrams Models with standard motors Wiring Diagrams Models with A...

Page 2: ...rants High efficiency and high strength fan guard Front access Internally enhanced tubing Convenient mounting brackets Ample electrical and header compartments Liquid line solenoid valve wire harness...

Page 3: ...10 x TD For R448A R449A use conversion factor 0 96 R407A R407A R407C R448A R448A R449A R449A Medium Temperature 6 FPI Models KLP LOW PROFILE EVAPORATORS Model KLP Qty Fans Evaporator Temperature Sele...

Page 4: ...e of 8 to 15 F 4 4 to 8 3 C are directly proportional to TD or use formula Capacity Rated capacity 10 x TD For R448A R449A use conversion factor 0 96 R404A R507 Low Temperature 6 FPI Models Model KLP...

Page 5: ...ge of 8 to 15 F 4 4 to 8 3 C are directly proportional to TD or use formula Capacity Rated capacity 10 x TD For R448A R449A use conversion factor 0 96 R404A R507 Low Temperature 4 FPI Models Model KLP...

Page 6: ...S1D 1 1 15 1 0 60 1 3 15 106L S1D 1 1 15 1 0 60 1 3 15 207L S1D 2 1 15 2 0 120 2 3 15 209L S1D 2 1 15 2 0 120 2 3 15 211L S1D 2 1 15 2 0 120 2 3 15 314L S1D 3 1 15 3 0 180 3 3 15 316L S1D 3 1 15 3 0...

Page 7: ...5L S2D 1 1 15 0 6 60 0 8 15 106L S2D 1 1 15 0 6 60 0 8 15 207L S2D 2 1 15 1 2 120 1 4 15 209L S2D 2 1 15 1 2 120 1 4 15 211L S2D 2 1 15 1 2 120 1 4 15 314L S2D 3 1 15 1 8 180 2 0 15 316L S2D 3 1 15 1...

Page 8: ...3 8 15 106LE 1 1 15 0 6 60 0 8 15 1060 4 6 5 8 15 3 0 3 8 15 207LE 2 1 15 1 2 120 1 4 15 1890 8 2 10 3 15 5 3 6 7 15 209LE 2 1 15 1 2 120 1 4 15 1890 8 2 10 3 15 5 3 6 7 15 211LE 2 1 15 1 2 120 1 4 1...

Page 9: ...15 211L S1D 2 1 15 1 2 120 1 4 15 410 3 6 4 5 15 314L S1D 3 1 15 1 8 180 2 0 15 560 4 9 6 1 15 316L S1D 3 1 15 1 8 180 2 0 15 560 4 9 6 1 15 418L S1D 4 1 15 2 4 240 2 6 15 720 6 3 7 8 15 421L S1D 4 1...

Page 10: ...0 5 0 15 207L S2D 6 2 1 15 1 2 120 1 4 15 410 1 8 2 2 15 209L S2D 2 1 15 1 2 120 1 4 15 410 1 8 2 2 15 211L S2D 2 1 15 1 2 120 1 4 15 410 1 8 2 2 15 314L S2D 3 1 15 1 8 180 2 0 15 560 2 4 3 0 15 316L...

Page 11: ...K30 KLPD PDI 4 14 10 20 11 115 1 60 208 230 1 60 Air Defrost Models WIRING DIAGRAMS KLP LOW PROFILE EVAPORATORS...

Page 12: ...K30 KLPD PDI 4 14 10 20 12 208 230 1 60 Electric Defrost Models WIRING DIAGRAMS KLP LOW PROFILE EVAPORATORS...

Page 13: ...K30 KLPD PDI 4 14 10 20 13 208 230 1 60 Electric Defrost Models with Multiple Evaporators WIRING DIAGRAMS KLP LOW PROFILE EVAPORATORS...

Page 14: ...K30 KLPD PDI 4 14 10 20 14 115 1 60 208 230 1 60 Hot Gas Defrost Models WIRING DIAGRAMS KLP LOW PROFILE EVAPORATORS...

Page 15: ...h evaporator fan management Energy savings with reduction in the number of defrost cycles Defrost heater management Improved system diagnostics and service through advanced alarm notification text ema...

Page 16: ...K30 KLPD PDI 4 14 10 20 16 115 1 60 Air Defrost Models with WIRING DIAGRAMS KLP LOW PROFILE EVAPORATORS...

Page 17: ...K30 KLPD PDI 4 14 10 20 17 208 230 1 60 Air Defrost Models with WIRING DIAGRAMS KLP LOW PROFILE EVAPORATORS...

Page 18: ...K30 KLPD PDI 4 14 10 20 18 208 230 1 60 1 3 Fan Electric Defrost Models with Max 12A WIRING DIAGRAMS KLP LOW PROFILE EVAPORATORS...

Page 19: ...K30 KLPD PDI 4 14 10 20 19 208 230 1 60 4 5 Fan Electric Defrost Models with 16A to 20A WIRING DIAGRAMS KLP LOW PROFILE EVAPORATORS...

Page 20: ...K30 KLPD PDI 4 14 10 20 20 208 230 1 60 6 Fan Electric Defrost Models with 24A WIRING DIAGRAMS KLP LOW PROFILE EVAPORATORS...

Page 21: ...449A 104M 9 00 9 00 9 00 106M 9 00 9 00 9 00 107M 9 00 9 00 9 00 209M 9 00 9 00 9 00 211M 9 00 9 00 9 00 214M 9 00 9 00 9 00 317M 9 00 9 00 9 00 320M 9 00 9 00 9 00 422M 9 00 9 00 9 00 427M 9 00 9 00...

Page 22: ...7 8 418L 4 78 1 4 1988 32 5 8 829 32 5 8 829 1 1 8 1 2 1 2 7 8 421L 78 1 4 1988 32 5 8 829 32 5 8 829 1 1 8 7 8 5 8 7 8 526L 5 94 1 4 2394 32 5 8 829 48 5 8 1235 1 3 8 7 8 5 8 1 1 8 631L 6 110 1 4 280...

Page 23: ...23 107ME 106LE 106VE 53 24 209ME 207LE 207VE 76 35 211ME 209LE 208VE 80 36 214ME 211LE 211VE 84 38 317ME 314LE 313VE 109 49 320ME 316LE 316VE 115 52 422ME 418LE 418VE 127 58 427ME 421LE 421VE 145 66...

Page 24: ...EBQSE A ZP 3 EBQVE AA ZP 3 207LE S2D EBQSE A ZP 3 EBQVE A ZP 3 209LE S2D EBQSE A ZP 3 EBQVE A ZP 3 211LE S2D EBQSE B ZP 3 EBQVE A ZP 3 314LE S2D EBQSE B ZP 5 EBQVE B ZP 3 316LE S2D EBQSE C ZP 5 EBQVE...

Page 25: ...INSTALLED NOZZLE FACTORY INSTALLED EXPANSION VALVE FACTORY INSTALLED LIQUIDLINE SOLENOIDVALVE 104LE L1 2 E2V9 E3 105LE L3 4 E2V9 E3 106LE L1 E2V11 E3 207LE L1 E2V11 E3 209LE L1 1 2 E2V11 E3 211LE L2...

Page 26: ...230 1 60 DFK 02 FP 020 DFK 09 FP 021 640ME T3D 208 230 3 60 DFK 03 FP 014 DFK 07 FP 019 Medium Temperature 6 FPI Low Temperature 6 FPI TEMP FPI of Fans Model KLP Voltage 1 X EVAPORATOR 2 X EVAPORATOR...

Page 27: ...008 208VE T3D 208 230 3 60 DFK 03 FP 013 DFK 07 FP 018 211VE S2D 208 230 1 60 DFK 02 FP 004 DFK 06 FP 008 211VE T3D 208 230 3 60 DFK 03 FP 013 DFK 07 FP 018 3 313VE S2D 208 230 1 60 DFK 02 FP 004 DFK...

Page 28: ...t 1x 50A 3P FanCont 1x 40A 3P FB 1x 30A 2P FB 1x 60A 2P 1 DFK 22 Time Clock HtrCont 1x 50A 3P FanCont 1x 40A 3P FB 1x 30A 3P FB 1x 60A 3P 2 DFK 23 Time Clock HtrCont 1x 50A 3P FanCont 1x 40A 3P FB 2x...

Page 29: ...MP Package Part Number Description FP 054 FUSES 3 15AMP 6 35AMP FP 055 FUSES 2 15AMP 2 45AMP FP 056 FUSES 2 15AMP 2 40AMP FP 057 FUSES 2 20AMP 3 50AMP FP 058 FUSES 2 15AMP 3 45AMP FP 059 FUSES 2 15AMP...

Page 30: ...ator capacity The nominal rating is based at 10 F T D 5 6 C Entering Air Temp minus Evap Temp Note that a higher lower operating T D will increase decrease this capacity rating by their direct ratio w...

Page 31: ...is reduced to approximately 25o F 4 C It is normal for the fans to cycle a few times until the room temper ature is brought down At higher evaporating temperatures this control may not close and there...

Page 32: ...Y PIPING WITH DRAIN PAN HEATER Standard Offering All Models Check Valve is included with the coil shipped loose as it is a must have component for system operation Check Valve TXV See next page OPT 1...

Page 33: ...HOT GAS ENTERING HOT GAS FACTORY PIPING H WITH HOT GAS DRAIN PAN LOOP WITH TXV BY OTHERS OR FACTORY INSTALLED WITH CHECK VALVE MTD CONNECTED TO LOOP 3 PIPE DEFROST EVAPORATOR COIL DISTRIBUTOR TXV CHE...

Page 34: ...K30 KLPD PDI 4 14 10 20 34 System Model Number Date of Start Up Serial Number Service Contractor Refrigerant Phone Electrical Supply E mail PROJECT INFORMATION KLP LOW PROFILE EVAPORATORS...

Page 35: ...x529 web www k rp com parts email parts k rp com call 1 844 893 3222 x520 web www k rp com warranty email warranty k rp com call 1 844 893 3222 x507 email orders k rp com call 1 844 893 3222 x501 emai...

Page 36: ...o the manufacturer s policy of continuous product improvement we reserve the right to make changes without notice KeepRite Refrigeration Brantford ON Longview TX 1 800 463 9517 info k rp com www k rp...

Reviews: