Operation Manual ServoOne Supply Unit
68
ID no.: 1101.21B.6-00 Date: 04/2020
5.4.4
Ethernet IP address menu (IP)
An Ethernet TCP/IP port is available as a service and diagnostics interface. The IP
address is set in the factory to 192.168.39.5. It can be changed using the PC software
DriveManager 5 or via the display.
Menu level Param-
eter
Value
range
Meaning
Explanation
1
2
IP
Iu
b0
00..FF
IP address
update byte 0
Setting for byte 0 of the IP address
in hexadecimal format (e.g. "05" in
192.168.39.5)
b1
00..FF
IP address
update byte 1
Setting for byte 1 of the IP address
in hexadecimal format (e.g. "27" in
192.168.39.5)
b2
00..FF
IP address
update byte 2
Setting for byte 2 of the IP address
in hexadecimal format (e.g. "A8" in
192.168.39.5)
b3
00..FF
IP address
update byte 3
Setting for byte 3 of the IP address
in hexadecimal format (e.g. "C0" in
192.168.39.5)
Ir
-
-
IP reset to
factory setting
Reset IP address to factory setting
(192.168.39.5)
Su
b0
00..FF
Subnet mask
update byte 0
Setting for byte 0 of the subnet mask
in hexadecimal format (e.g. "00" in
255.255.255.0)
b1
00..FF
Subnet mask
update byte 1
Setting for byte 1 of the subnet mask
in hexadecimal format (e.g. "FF" in
255.255.255.0)
b2
00..FF
Subnet mask
update byte 2
Setting for byte 2 of the subnet mask
in hexadecimal format (e.g. "FF" in
255.255.255.0)
b3
00..FF
Subnet mask
update byte 3
Setting for byte 3 of the subnet mask
in hexadecimal format (e.g. "FF" in
255.255.255.0)
Sr
-
-
Subnet mask
reset to factory
setting
Reset subnet mask to factory setting
(255.255.255.0)
Table 5.9 IP address menu
5.4.3
Parameter menu (PA)
The following functions are available on the Parameter menu:
y
Reset device to factory settings
Menu level
Parameter
Value
range
Meaning
Explanation
1
2
PA
Pr
-
-
Parameter reset
Reset device settings to factory settings.
Table 5.7 Parameter menu
Error messages displayed during user data entry
A failed user action is indicated by an error message. The message consists of the
alternating display of "Er" and the error number.
NOTe:
The error messages displayed during user data entry should not be confused
with drive error messages. You will find detailed information on the error codes
and on error management in the device help.
Error number
Meaning
00
File system no error
01
File system any file system error
02
File system command rejected
03
File system function parameter invalid
04
File system create file error
05
File system open file error
17
Parameter reset to factory settings failed
18
Parameter write access failed
19
Save parameter data set non volatile failed
20
Not all parameters written
21
Error while reset to factory settings
Table 5.8 Error messages displayed during user data entry
Commissioning
Summary of Contents for ServoOne Series
Page 6: ...Operation Manual ServoOne Supply Unit 6 ID no 1101 21B 6 00 Date 04 2020 Table of contents ...
Page 10: ...Operation Manual ServoOne Supply Unit 10 ID no 1101 21B 6 00 Date 04 2020 ...
Page 90: ...Operation Manual ServoOne Supply Unit 90 ID no 1101 21B 6 00 Date Date 04 2020 Glossary ...
Page 91: ...Operation Manual ServoOne Supply Unit 91 ID no 1101 21B 6 00 Date 04 2020 ...