Operation Manual ServoOne Supply Unit
62
ID no.: 1101.21B.6-00 Date: 04/2020
y
Set the mains frequency P-0452.
y
Set automatic mains frequency detection parameter 0449 to 1.
Figure 5.2 Parameter editor - parameter P-0452
NOTe:
So that the parameters are also effective after a restart, the modified settings
must be saved in the device in non-volatile memory and a 24-V reset
undertaken.
Saving setting
1.
To save the parameter setting in the device, please click the "Save setting in
device to non-volatile memory" button.
2.
In addition, it is possible to save the parameter data set as a file on the PC
connected. For this purpose click the "Save actual device setting to file", select
the required folder and accept the save process by clicking the "Save" button
using the mouse.
Figure 5.3 Saving setting
1
2
5.2.5
Setting mains voltage and mains frequency of the supply
system
4.
The supply unit parameters are configured in the factory for a system with
3 x 400 V AC (50 Hz). If the supply unit is to be operated on such a system, you
can continue with step 5. If the supply unit is to be operated on a different system,
the parameters P-0307 mains voltage and P-0452 mains frequency must be set to
the corresponding values.
NOTe:
Only the fixed mains voltages 400 V, 460 V and 480 V and the mains
frequencies 50 Hz and 60 Hz can be set.
The supply unit regulates the DC link voltage to an internally specified fixed setpoint.
At an input voltage of 400 V
AC
the DC link voltages 650 and 770 V
DC
are possible.
At an input voltage of 460 and 480 V
AC
the DC link voltage 770 V
DC
is possible.
y
Set the mains voltage P-0307.
Figure 5.1 Parameter editor - parameter P-0307
Commissioning
Summary of Contents for ServoOne Series
Page 6: ...Operation Manual ServoOne Supply Unit 6 ID no 1101 21B 6 00 Date 04 2020 Table of contents ...
Page 10: ...Operation Manual ServoOne Supply Unit 10 ID no 1101 21B 6 00 Date 04 2020 ...
Page 90: ...Operation Manual ServoOne Supply Unit 90 ID no 1101 21B 6 00 Date Date 04 2020 Glossary ...
Page 91: ...Operation Manual ServoOne Supply Unit 91 ID no 1101 21B 6 00 Date 04 2020 ...